User manual FLUKE RPM4-AD

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE RPM4-AD. We hope that this FLUKE RPM4-AD user guide will be useful to you.


FLUKE RPM4-AD : Download the complete user guide (2633 Ko)

Manual abstract: user guide FLUKE RPM4-AD

Detailed instructions for use are in the User's Guide.

[. . . ] RPM4-ADTM Reference Pressure Monitor, Air Data Version Operation and Maintenance Manual © 2005-2007 DH Instruments, a Fluke Company High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High pressure systems should be assembled and operated only by personnel who have been instructed in proper safety practices. This instrument is not to be operated in any other manner than that specified by the manufacturer. © 2005-2007 DH Instruments, a Fluke Company All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of DH Instruments, a Fluke Company 4765 East Beautiful Lane, Phoenix AZ 85044-5318, USA. [. . . ] It is recommended that the low security level be maintained at all times. If there is a risk of unauthorized changing of the security level, changing authority should be password protected (see OPERATION of this section). The security levels are structured to support typical levels of operation as shown in Table 12. Specifically, the security levels prevent execution of the functions accessed by the key strokes marked by "·": Low Medium High © 2005-2007 DH Instruments, a Fluke Company Page 68 3. Security levels FUNCTION [RANGE] [ENT] [UNIT] [MODE] [AutoRange] [LEAK CK] [DISPLAY] [HEAD] [SDS] [AutoZ] (in absolute mode) [SETUP] [SETUP], <1range> [SETUP], <2res> [SETUP], <4UL> [SPECIAL] [SPECIAL], <1AutoZ> [SPECIAL], <1AutoZ>, <1on/1off> [SPECIAL], <1AutoZ>, <3edit> [SPECIAL], <2remote> [SPECIAL], <2remote>, make changes [SPECIAL], <3head> [SPECIAL], <4SDS> [SPECIAL], <5pref>, <1ScrSvr> [SPECIAL], <5pref>, <2sound> [SPECIAL], <5pref>, <3time> [SPECIAL], <5pref>, <3time>, make changes SPECIAL], <5pref>, <4ID>, <2edit> [SPECIAL], <6Punit> [SPECIAL], <7internal> [SPECIAL], <7internal>, <3RPT2x> [SPECIAL], <7interrnal>, <5log>, clear log [SPECIAL], <8cal> [SPECIAL], <8cal>, <2edit> under any selection [SPECIAL], <4reset> [SPECIAL], <4reset>, <4cal> [SPECIAL], <4reset>, <5all> Remote communications disabled "·" indicates the function/menu is NOT accessible. LOW MEDIUM HIGH · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 69 © 2005-2007 DH Instruments, a Fluke Company RPM4-ADTM OPERATION AND MAINTENANCE MANUAL OPERATION RPM4-AD is delivered with no active password and access to the User Level menu is open. To access the LEVEL function press [SPECIAL], <5prefs>, <5level>. The display is: Selecting <1change user level> brings up the restriction menu: 1change user level 2edit password Restrictions: 1none 2low 3medium 4high Select a different level or The cursor is on the current restriction level. If no password is active, selecting <2edit password> displays the user password and allows it to be edited. Password: pppppp 0 disables password Once a password has been entered, the user level cannot be changed without reentering the password. Passwords can be up to six numbers in length and cannot start with a zero. If <0> is entered, the password is made inactive and the user will not be required to enter a password to access the user level menu. This condition, with a security level of <2low>, is the factory default. If there is an active password, the RPM4-AD password entry screen appears. The user must enter the user defined password or the factory secondary password to proceed further: RPM4 SNnnnn-xx Password: pppppp The first field, <nnnn>, is the serial number of the RPM4, followed by a second field, <xx>, that represents the number of times that a secondary password has been used. The second field, <xx>, increments each time a secondary password is used. The third field, <pppppp> is for user entry of the normal password. The factory secondary password is available in case the user's password has been misplaced or forgotten. It can be obtained by contacting a DHI Authorized Service Center (see Table 34). The factory secondary password is different for all RPM4's and changes each time it is used. 3. 5. 6 <6PUNIT> PURPOSE To customize the choice of units of measure available in the [UNIT] key menus. PRINCIPLE The [UNIT] function key makes available a choice of six default units of measure depending on the active Q-RPT and measurement mode (see Section 3. 3. 2 and Table 9, Table 10). RPM4-AD also supports many commonly used units that are not included in the default set up. These units can be made available for active selection by customizing the UNIT function using [SPECIAL], <6PresU>. [. . . ] The designation of a the Q-RPT with the lower full scale default range in RPM4s with two Q-RPTs. Whether pressure is being measured relative to absolute zero or vacuum (absolute mode) or relative to atmospheric pressure (gauge mode). Measurement mode in which the Q-RPT indicates gauge pressure (difference from atmospheric pressure), in both positive and negative directions (above and below atmosphere). The difference between a Q-RPT reading and the AutoZero reference at the time AutoZ is run. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE RPM4-AD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE RPM4-AD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.