User manual EUTECH INSTRUMENTS ION 2700

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ION 2700. We hope that this EUTECH INSTRUMENTS ION 2700 user guide will be useful to you.


EUTECH INSTRUMENTS ION 2700 : Download the complete user guide (1372 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS ION 2700

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual 2700 Series Benchtop Meters pH 2700 ION 2700 CON 2700 DO 2700 PC 2700 Technology Made Easy . . . Part of Thermo Fisher Scientific 68X544001 Rev 1 Sep 2010 TABLE OF CONTENTS 1. Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. Getting Started. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Keypad and Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Navigation of Tabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Meter Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3. System Setup & Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Stability Criteria. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Auto Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Print Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Date & Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Clear Datalog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Factory Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Contrast Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 4. [. . . ] For best results always begin with your lowest calibration standard value, followed by the next lowest, and so on. Low conductivity standard solutions (less than 20 µS) are unstable and are very temperature dependent. As a result, reproducible calibration results are challenging in lowest measurement range #1 (0. 00 to 20. 0 µS). "2 Cell' or "4 Cell' electrode is automatically detected and displayed on the measurement screen when connected. 24 12. Conductivity, TDS, Salinity, & Resistivity Calibration (manual adjustment) For best results, periodic calibration with known accurate standards is recommended prior to measurement. Calibrate with standards that are close in value to your intended sample(s). When using multi-point calibration, perform a calibration in each range that you expect to use for best results. If the electrode has been stored dry for some time, soaking in alcohol or clean water for a few minutes can help performance. Rinse the electrode with clean water then submerse into your calibration standard. 3) Use the up/down arrows to adjust the cell constant manually or press NEXT to keep the nominal cell constant value and proceed with a typical manual calibration (recommended). If adjusting the cell constant manually, press ENTER after `Stable' appears to confirm the adjustment. Before and after a manual calibration constant adjustment 4) The upper display is the active reading while the lower display is the factory default value without calibration. Use the up/down arrows to adjust the upper display to match the desired calibration value. The calibrated value, Range (R) that was calibrated and the calculated cell constant are now shown. 25 Before and after a manual calibration 5) For multi-point calibration repeat with additional standards. Press ESC to save calibration or press NEXT to view the calibration report. Additional manual calibration notes: A maximum of one calibration point per range can be performed. If multiple calibration points are used in the same range, the most recent one will replace the previous one. When the electrode is replaced, it is best to clear the calibration to the factory default values. Rinse or immerse the probe before calibration and between samples with clean water (deionized water is ideal). To protect from erroneous calibrations, the allowable tolerance is ±40% of the factory default value. For best results always begin with your lowest calibration standard value, followed by the next lowest, and so on. Low conductivity standard solutions (less than 20 µS) are unstable and are very temperature dependent. As a result, reproducible calibration results are challenging in lowest measurement range #1 (0. 00 to 20. 0 µS). Note: If using the 2-cell electrode, the protective probe guard can be removed temporarily for cleaning however it must be re-attached during measurement and calibration. Erroneous results will occur while the probe guard is removed. 26 13. Ion Setup from the Use Setup Ion mode to customize this parameter. Press measurement screen and then press ENTER when ION is selected. Sample ID This is a user selectable number from 1 to 99999. [. . . ] AUTO calibration values (84 µS, 1413 µS, 12. 88 mS, or 111. 8 mS) are not used. Ensure stirrer motor is on during solution measurement and temperature is stable. If electrode is old, gold cathode may be tarnished--buff with disk or pencil eraser. Replace membrane, electrolyte and recondition Ion Display reads "- - -" Conductivity Can't adjust / can't calibrate Conductivity 2nd Calibration point replaces the 1st TDS Standard does not match DO Reading is very slow to stabilize 45 sensor. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ION 2700




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ION 2700 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.