User manual EUTECH INSTRUMENTS ECFP21A1A1 DIFFERENTIAL PH SENSOR REV 0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ECFP21A1A1 DIFFERENTIAL PH SENSOR. We hope that this EUTECH INSTRUMENTS ECFP21A1A1 DIFFERENTIAL PH SENSOR user guide will be useful to you.


EUTECH INSTRUMENTS ECFP21A1A1 DIFFERENTIAL PH SENSOR REV 0: Download the complete user guide (561 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS ECFP21A1A1 DIFFERENTIAL PH SENSORREV 0

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual ECFP21A1A1 Differential pH Sensor 1 ½ Inch NPT Mounting Threads Copyright © 2006 All rights reserved. Eutech Instruments Pte Ltd 68X216866 Rev 0 10/04 Blk 55, Ayer Rajah Crescent, #04-16/24 Singapore 139949 +65 6778 6876 +65 67730836 fax www. thermofisher. com TABLE OF CONTENTS TABLE OF CONTENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 PREFACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SAFETY INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Use a watertight cord grip to insert the sensor cable and the interconnect cable into the junction box that has a terminal strip designed to make the proper connections. Connect both the sensor cable wires and the interconnect wires to the terminal strip. Use a watertight cord grip to insert the sensor cable into the Alpha pH2000D Controller. Conduit holes are found on the bottom of the Alpha pH2000D controller for this purpose. Connect the sensor wires to the Alpha pH2000D controller as outlined in the controller manual. Be sure that the wire colors of the sensor cable match those of the interconnect cable on either side of the terminal strip. Connect the sensor wires into the Alpha pH2000D sensor terminal block as shown in the Alpha pH2000D manual. Remove the protective cap from the sensor head and make sure moisture is present and that the salt bridge has not dried out. If the protective cap is dry, the sensor should be hydrated in tap water for at least 1 hour prior to calibration. It is recommended to use a 2-point buffer calibration on installation of the sensor. If measurement response time is slow or if the sensor will not calibrate, refer to Section 4 for maintenance, refurbishment and troubleshooting suggestions. Insert the sensor into the tee and slowly turn clockwise until secure. Be sure the pipe remains full when the sensors are installed. 2. 3. 3. 2. 2. Immersion Mounting For immersion mounting applications the sensor is connected to a 1½ inch extension pipe to protect the cable from damage and to reduce the possibility of leaks that may damage the sensor. Figure 3. 5: Immersion mounting assembly www. thermofisher. com Detailed Insertion Mount Installation Instructions 1. Attach the sensor to the 1. 5 inch NPT coupling by turning the sensor in a clockwise direction until secure. Either route the cable directly to the Alpha pH2000D or splice the wires in a junction box and use an extension cable. Insert the cable into the Alpha pH2000D controller through a watertight cord grip. Conduit holes are provided for the cord grip on the bottom of the Alpha pH2000D controller. Connect the sensor wires into the Alpha pH2000D sensor terminal block as shown in the Alpha pH2000D manual. Remove the protective cap from the sensor head and make sure moisture is present and that the salt bridge has not dried out. If the protective cap is dry, the sensor should be hydrated in tap water for at least 1 hour prior to calibration. It is recommended to use a 2-point buffer calibration on installation of the sensor. [. . . ] Disconnect the RED and GREEN sensor wires from the analyzer terminal block while leaving the other wires connected. Connect the (+) lead of a millivolt meter to the RED wire and the (-) lead of the millivolt meter to the GREEN wire. Stir the sensor for 10 to 15 seconds and then allow the sensor to stabilize in solution for about 2 minutes. If the reading is higher or lower than specified, replace the salt bridge and filling solution and try again. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ECFP21A1A1 DIFFERENTIAL PH SENSOR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ECFP21A1A1 DIFFERENTIAL PH SENSOR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.