User manual EUTECH INSTRUMENTS ALPHA PH 500

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA PH 500. We hope that this EUTECH INSTRUMENTS ALPHA PH 500 user guide will be useful to you.


EUTECH INSTRUMENTS ALPHA PH 500 : Download the complete user guide (500 Ko)

You may also download the following manuals related to this product:

   EUTECH INSTRUMENTS ALPHA PH 500 REV 6 (391 ko)

Manual abstract: user guide EUTECH INSTRUMENTS ALPHA PH 500

Detailed instructions for use are in the User's Guide.

[. . . ] Alpha pH 500 2-Wire Transmitter pH / ORP ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. patent 6, 793, 787. AQUAfast, Cahn, ionplus, KNIpHE, No Cal, ORION, perpHect, PerpHecT, PerpHecTion, pHISA, pHuture, Pure Water, Sage, Sensing the Future, SensorLink, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS and TURBO2 are registered trademarks of Thermo Fisher. 1-888-pHAX-ION, A+, All in One, Aplus, AQUAsnap, AssuredAccuracy, AUTOBAR, AUTO-CAL, AUTO DISPENSER, Auto-ID, AUTO-LOG, AUTO-READ, AUTOSTIR, Auto-Test, BOD AutoEZ, Cable-Free, CERTI-CAL, CISA, DataCOLLECT, DataPLUS, digital LogR, DirectCal, DuraProbe, Environmental Product Authority, Extra Easy/Extra Value, FAST QC, GAP, GLPcal, GLPcheck, GLPdoc, ISEasy, KAP, LabConnect, LogR, Low Maintenance Triode, Minimum Stir Requirement, MSR, NISS, One-Touch, One-Touch Calibration, One-Touch Measurement, Optimum Results, Orion Star, Pentrode, pHuture MMS, pHuture Pentrode, pHuture Quatrode, pHuture Triode, Quatrode, QuiKcheK, rf link, ROSS Resolution, SAOB, SMART AVERAGING, Smart CheK, SMART STABILITY, Stacked, Star Navigator 21, Stat Face, The Enhanced Lab, ThermaSense, Triode, TRIUMpH, Unbreakable pH, Universal Access are trademarks of Thermo Fisher. Guaranteed Success and The Technical Edge are service marks of Thermo Fisher. PerpHecT meters are protected by U. S. patents 5, 198, 093, D334, 208 and D346, 753. ionplus electrodes and Optimum Results solutions are protected by U. S. and its subsidiaries. The specifications, descriptions, drawings, ordering information and part numbers within this document are subject to change without notice. This publication supersedes all previous publications on this subject. Preface This manual serves to explain the use of the Alpha pH 500 transmitter. [. . . ] 5. 6. 3 Temperature Compensation Setting (Unavailable in ORP mode) pH values other than pH 7. 00 are affected by temperature. Under varying temperature conditions, use ATC to compensate pH values. If temperature of bath is constant, and a temperature probe is not available, Manual Temperature Compensation can be utilized. 6. 3. 1 Automatic Temperature Compensation For automatic temperature compensation (ATC), connect ATC probe to transmitter, as described in Section 2. 2. 2. Press or keys to scroll o through sub-menus till LCD displays `SET C'. Use or keys to select `ATC On', and press ENT. Dip ATC probe into a solution of known temperature (i. e. Allow time for temperature probe to acclimatize with surrounding bath temperature. If temperature readings are inaccurate, calibrate temperature probe as described in steps 4 and 5. If temperature readings are correct, press ENT key and go to step 6. NOTE: If you are using a temperature probe, the probe must be submersed in the liquid you are measuring. 6. 3. 2 1. Manual Temperature Compensation Make sure the transmitter is on. Primary display shows `ATC' and secondary display shows `On' or `OFF'. Primary display shows temperature (default is 25. 0), and secondary display shows `P °C''. This is the set up page for setting the temperature of your transmitter to the temperature of your process or sample by using an accurate thermometer as reference. Use or keys to set the transmitter to the temperature of your process or sample. Primary display shows temperature (default is 25. 0), and secondary display shows `C °C'. This is the set up page to input to your transmitter the temperature of your calibration solutions. Use or keys to set the transmitter to the temperature of your calibration solutions. 7. The transmitter will now compensate pH readings for the manually set temperature (values taken from P °C'). SETUP HOLD SETUP HOLD SETUP HOLD SETUP HOLD SETUP . . HOLD °C ATC . SETUP HO LD . Temperature Compensation Setting Chart ­ alpha pH 500 Transmitter 6. 4 HOLD Current Setting SETUP HOLD When Transmitter is in CAL or SETUP modes, it automatically goes into a `HOLD' mode. To indicate Transmitter is in `HOLD' mode, output current can be set to 22 mA output by activating the `HLD On'. Press ENT key and use or keys to scroll till LCD displays `SEt' in the upper display; and `HLd' in the lower display. and keys together, to return to MEAS SETUP HOLD 2. SETUP HOLD 3. NOTE: If `HLd' is set to `OFF', then current output will be equivalent to last measured value. 6. 5 SETUP HOLD Out-of-Range Current Setting If pH or ORP readings exceed the scale, LCD displays `Or' (overrange), or `Ur' (under-range). Transmitter current output can be set to 3. 8 mA to indicate Out-of Range situation. Press ENT key and use or keys to scroll till LCD displays `SEt' in the upper display; and `org' in the lower display. Press and keys together, to return to MEAS mode. SETUP HOLD 2. SETUP HOLD 3. NOTE: If `org' is set to `OFF', under-range will be set at 4 mA, while over-range will be set at 20 mA. 6. 6 6. 6. 1 SETUP HOLD Configuration Selecting pH or ORP Mode of Operation The alpha pH 500 transmitter is not only a pH transmitter, but also an ORP transmitter. [. . . ] Replace with new electrode ­ call your distributor for information. 8 TROUBLE SHOOTING GUIDE Cause a). See "Probe Care & Maintenance", Section 7. Problem Power on but no display Unstable readings Slow response a). Dirty / Oily probe. 9 SPECIFICATIONS DESCRIPTIONS 0. 00 to 14. 00 pH Resolution / Accuracy 0. 01 pH / ± 0. 01 pH -10. 0 to 110. 0 °C 0. 1 °C / ± 0. 5 for °C -1000 to +1000 mV 1 mV / ± 2 mV Auto (Pt 100) / Manual (from 0 to 100 °C) 2 USA: 4. 01, 7. 00, 10. 01; NIST: 4. 01, 6. 86, 9. 18 Asymmetrical / Symmetrical 4. 0 to 20. 0 mA (Galvanically Isolated) SPECIFICATIONS pH Range Temperature Range Resolution / Accuracy Millivolt Range Resolution / Accuracy Temperature Compensation Number of calibration points Number of calibration buffers Inputs Output Over- / Under range current output `ON' Select `OFF' Select HOLD current output `ON' Select `OFF' Select Display Power Requirements Load Resistance Dimension / Weight 3. 8 mA 4 mA (under-range) & 20 mA (over-range) 22 mA Last measured current value Custom Dual LCD 12 to 24 VDC Max. 600 96 x 96 x 66 mm / 210 g 10 TECHNICAL DIMENSIONS 11 ACCESSORIES THERMO SCIENTIFIC Replacement Transmitter and Transmitter accessories Ordering Code No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA PH 500




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA PH 500 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.