User manual EUTECH INSTRUMENTS ALPHA COND 500

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA COND 500. We hope that this EUTECH INSTRUMENTS ALPHA COND 500 user guide will be useful to you.


EUTECH INSTRUMENTS ALPHA COND 500 : Download the complete user guide (513 Ko)

You may also download the following manuals related to this product:

   EUTECH INSTRUMENTS ALPHA COND 500 REV 3 (563 ko)
   EUTECH INSTRUMENTS ALPHA COND 500 REV 4 (400 ko)

Manual abstract: user guide EUTECH INSTRUMENTS ALPHA COND 500

Detailed instructions for use are in the User's Guide.

[. . . ] Alpha CON 500 Transmitter uS / mS / ºC ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. patent 6, 793, 787. AQUAfast, Cahn, ionplus, KNIpHE, No Cal, ORION, perpHect, PerpHecT, PerpHecTion, pHISA, pHuture, Pure Water, Sage, Sensing the Future, SensorLink, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS and TURBO2 are registered trademarks of Thermo Fisher. 1-888-pHAX-ION, A+, All in One, Aplus, AQUAsnap, AssuredAccuracy, AUTOBAR, AUTO-CAL, AUTO DISPENSER, Auto-ID, AUTO-LOG, AUTO-READ, AUTOSTIR, Auto-Test, BOD AutoEZ, Cable-Free, CERTI-CAL, CISA, DataCOLLECT, DataPLUS, digital LogR, DirectCal, DuraProbe, Environmental Product Authority, Extra Easy/Extra Value, FAST QC, GAP, GLPcal, GLPcheck, GLPdoc, ISEasy, KAP, LabConnect, LogR, Low Maintenance Triode, Minimum Stir Requirement, MSR, NISS, One-Touch, One-Touch Calibration, One-Touch Measurement, Optimum Results, Orion Star, Pentrode, pHuture MMS, pHuture Pentrode, pHuture Quatrode, pHuture Triode, Quatrode, QuiKcheK, rf link, ROSS Resolution, SAOB, SMART AVERAGING, Smart CheK, SMART STABILITY, Stacked, Star Navigator 21, Stat Face, The Enhanced Lab, ThermaSense, Triode, TRIUMpH, Unbreakable pH, Universal Access are trademarks of Thermo Fisher. Guaranteed Success and The Technical Edge are service marks of Thermo Fisher. PerpHecT meters are protected by U. S. patents 5, 198, 093, D334, 208 and D346, 753. ionplus electrodes and Optimum Results solutions are protected by U. S. and its subsidiaries. The specifications, descriptions, drawings, ordering information and part numbers within this document are subject to change without notice. This publication supersedes all previous publications on this subject. Preface This manual serves to explain the use of the Alpha COND 500 transmitter. [. . . ] It is important to ensure that temperature calibration is carried out first prior to conductivity calibration since temperature readings affect the accuracy of conductivity measurements. Your transmitter allows a one point temperature calibration using reference of a thermometer known to be accurate. Please refer to Section 6. 2 - Temperature Compensation Setting for temperature calibration procedure. 5. 3 Conductivity Calibration MEAS A 1-point Calibration is required for this transmitter. If the calibration process is aborted, your transmitter will revert to the previous calibration data. Organize your calibration standard solution in two beakers ­ one for rinsing and the other for calibration. Rinse the electrode in de-ionized water and then rinse with the calibration standard. Dip the electrode to the calibration standard intended for calibration and swirl gently to create a homogenous sample. The upper display will show the measured reading based on the last calibration setting whereas the lower display will show the measured default reading of the standard. Use the or keys to adjust the upper display to the calibration standard value. HOLD 1578 25. 5 S °C ATC CAL HOLD 1578 1578 S 4. CAL 5. Note: You can offset the conductivity reading within ± 40% from the default reading of the standard. The minimum allowable calibration point is 10% of the full scale reading of the range selected. 6. 1413 1578 S Press the ENTER key to confirm the calibration value and to return to the measurement mode. Note: To exit this program without confirming the calibration, press the and keys together (Escape). Note: When there is a calibration error, the buffer icon and ERR annunciator will appear together with a blinking electrode icon. Press both and keys together TWICE to return to the measurement mode. 6 ADVANCED SETUP FUNCTIONS The advanced setup mode lets you customize your transmitter's preferences and defaults. This transmitter features different sub groups that organize all setup parameters. The sub-groups are: 6. 1 Range and Zooming Selection Setting Your COND 500 transmitter provides six selections of conductivity measurement ranges to suit your process application needs. Zooming selection is available where both the 4 mA and 20 mA output current can be assigned to specific conductivity values for a more refined output. Use the or keys to scroll through the six ranges and press the ENT key to select your desired range. The transmitter will now switch to the zooming selection and display the low zoom value setup. SETUP HOLD SETUP HOLD 2. 3. 1. 9 99 1 S NOTE: Range 6 selection page will only appear in the setup mode when the cell constant is selected as K = 1. 0 or K = 10. Range 1 will only appear when cell constant is selected as K =0. 1 or K =1. 0 Six Range selection 4. For zooming setting, use the or keys to set the conductivity low zoom value for the 4 mA current and press the ENT key to confirm. Use the or keys again to set the conductivity high zoom value for the 20 mA current and press the ENT key to confirm and return to the range setup mode. Press both and keys together to return to the measurement mode. SETUP HOLD 0. 00 L S 5. SETUP HOLD 1. 9 99 Hi S 6. 6. 2 Temperature Compensation Setting Conductivity readings are affected by temperature. [. . . ] The display will show the current effective cell constant and its range. Press and keys together, to return to the measurement mode. HOLD ELE 2. 3. SETUP K= 1. 000 6 6. 10 Reset Function SETUP The reset function lets you choose to either reset the transmitter's conductivity calibration only or conductivity calibration plus all setup functions that you might have changed back to factory default settings. However, the temperature compensation setting, as in Section 6. 2, will remain unchanged. Use the or keys to scroll till LCD displays `rSt' in the upper display. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA COND 500




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA COND 500 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.