User manual EUTECH INSTRUMENTS ALPHA COND 200 REV 3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA COND 200. We hope that this EUTECH INSTRUMENTS ALPHA COND 200 user guide will be useful to you.


EUTECH INSTRUMENTS ALPHA COND 200 REV 3: Download the complete user guide (508 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS ALPHA COND 200REV 3

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual Alpha COND 200 1/8 DIN Conductivity Controller Transmitter S / mS / ºC 68X276103 | Rev. 3 | Apr 2008 PREFACE This manual serves to explain the use of the Alpha COND 200 controller/transmitter. This manual functions in two ways: firstly as a step-by-step guide to help you operate the meter; secondly as a handy reference guide. This manual is written to cover as many anticipated applications of the Alpha COND 200 controller/transmitter as possible. If there are doubts in the use of the Alpha COND 200 controller/transmitter, do not hesitate to contact your nearest lpha Authorized Distributor. [. . . ] P4. 0: Temperature Data P4. 1: select ATC or MTC P4. 2: select temperature coefficient value P4. 3: select normalization temperature P5. 0: Calibration Conductivity Buffer points P5. 1: view conductivity value at which calibration was performed P6. 0 Electrode Properties P6. 1: view cell constant value after calibration P6. 2: view temperature offset value after calibration (only if in ATC mode) P7. 0 Reset P7. 1: select yes/no to reset controller to factory defaults 15 7. 3 Set Point 1 ­ P1. 0 Setup program P1. 0 allows you to set parameters for relay 1. P1. 1: select relay 1 set point value P1. 2: select relay 1 as low or high set point P1. 3: set relay 1 hysteresis value (dead band) P . 0 1 S1 P P . 1 1 S1 P 200 P . 2 1 P. 13 S1 P H St Y LOW 0 10 HI H G Press and keys together (ESCAPE) at anytime, to leave Setup mode and return to Measurement mode. P1. 1: Select relay set point value Set the Conductivity value that will activate Relay 1. If measured value overshoots or undershoots Set Point value, Relay 1 will be activated and corresponding LED on front panel will light. Press ENTER to confirm and continue to step three of P1. 2, or press and keys together to return to P1. 0. Press and keys together again, to return to the Conductivity measurement mode. P1. 2: Set relay as high or low set point Select low set point to activate Relay when measured value undershoots Set point; select high set point to activate Relay when measured value overshoots Set point. Using both SP1 and SP2, you can select lo/lo, lo/hi, hi/lo or hi/hi set points. Press ENTER to confirm and continue to step 3 of P1. 3, or press and keys together to return to P1. 0. Press and keys together again, to return to Conductivity measurement mode. 16 P1. 3: Set Hysteresis value Hysteresis prevents rapid contact switching if measured value is fluctuating near the set point. Once activated, relay will not de-activate until measured value reaches set point plus hysteresis value. Example: Low set point is 200. 0 µS/cm and hysteresis 100. 0 µS/cm, relay will activate when value is below 200. 0 µS/cm, but will not de-activate till measured Conductivity value rises above 300. 0 µS/cm. The hysteresis window can be set to any value within the range shown below: 1. Press and keys together again, to return to Conductivity measurement mode. 17 7. 4 Set Point 2 ­ P2. 0 Setup program P2. 0 allows you to set parameters for relay 2. P2. 1: select relay 2 set point value P2. 2: select relay 2 as low or high set point P2. 3: set relay 2 hysteresis value (dead band) P2 . 0 S2 P P . 1 2 S2 P 00 18 P . 2 2 P23 . S2 P H St Y LOW 100 HI H G Press and keys together (ESCAPE) at anytime, to leave Setup mode and return to Measurement mode. P2. 1: Select relay set point value Set the Conductivity value that will activate Relay 2. If measured value overshoots or undershoots Set Point value, Relay 2 will be activated and corresponding LED on front panel will light. Press ENTER to confirm and continue to step three of P2. 2, or press and keys together to return to P2. 0. Press and keys together to return to Conductivity measurement mode. P2. 2: Set relay as high or low set point Select low set point to activate Relay when measured value undershoots Set point; select high set point to activate Relay when measured value overshoots Set point. Using both SP1 and SP2, you can select lo/lo, lo/hi, hi/lo or hi/hi set points. [. . . ] 9 TRANSMITTER FUNCTION If remote data logging is required, a 4-20 mA current loop can be connected. The current will be proportional to the Conductivity value displayed on the panel and according to the measurement range selected. Conductivity Range 0. 00 ­ 20. 00 µS/cm 0. 0 ­ 200. 0 µS/cm 0. 0 ­ 200. 0 µS/cm 0 ­ 2000 µS/cm 0. 00 ­ 10. 00 mS/cm 0. 00 ­ 20. 00 mS/cm 0. 0 ­ 200. 0 mS/cm 0. 0 ­ 200. 0 mS/cm Range No. , R 1 2 3 4 5 6 7 8 Cell Constant 0. 1 0. 1 1 1 1 1 1 10 4 mA current 0. 00 µS/cm 0. 0 µS/cm 0. 0 µS/cm 0 µS/cm 0. 00 mS/cm 0. 00 mS/cm 0. 0 mS/cm 0. 0 mS/cm 20 mA current 20. 00 µS/cm 200. 0 µS/cm 200. 0 µS/cm 2000 µS/cm 10. 0 mS/cm 20. 0 mS/cm 200. 0 mS/cm 200. 0 mS/cm The 4-20 mA current loop can drive a load resistance of no more than 200 . 25 10 SPECIFICATIONS Conductivity Range 0. 00 ­ 20. 00 µS/cm 0. 0 ­ 200. 0 µS/cm 0. 0 ­ 200. 0 µS/cm 0 ­ 2000 µS/cm 0. 00 ­ 10. 00 mS/cm 0. 00 ­ 20. 00 mS/cm 0. 0 ­ 200. 0 mS/cm 0. 0 ­ 200. 0 mS/cm Relative Accuracy Temperature Resolution/Accuracy Sensor Temperature Compensation Temperature Coefficient Set-point And Controller Functions Function Switching Conductivity Hysteresis Contact Outputs, Controller Switching Voltage / Current / Power Signal Output / Load Electrical Data And Connections Power Requirements Rated Input Current (MAX) Insulation Category Connection Terminals Main Fuse Resolution Cell Constant 0. 01 µS/cm 0. 1 0. 1 µS/cm 0. 1 0. 1 µS/cm 1 1 µS/cm 1 0. 01 mS/cm 1 0. 01 mS/cm 1 0. 1 mS/cm 1 0. 1 mS/cm 10 ± 1 % of full scale -10 to 110 oC 0. 1 / ± 0. 5 oC Pt 100 (3-wire) Automatic / Manual (0 to 50 °C) 0. 0 to 5. 0 % Limit Control 5% of full scale 2 SPDT relays Max 250 VAC / Max 3A / Max 600 VA 4-20 mA galvanically isolated / 200 85 to 260 VAC, 50/60 Hz or DC 100 mA II 3 Detachable connectors (3-pin; 7-pin & 9-pin terminal blocks) + 1 FIXED CONNECTOR 250 mA, Anti-surge (BUSSMAN S504+250mA) Environmental Conditions Ambient Temp. Humidity 10 to 95 % (non-condensing) Mechanical Specifications Dimensions (Panel Housing ­ W x H x D) 96 x 48 x 150 mm Weight 300g (350g boxed) 26 11 ACCESSORIES Product Description Conductivity cell, Epoxy body, Graphite sensor, w/3-wire Pt100, k = 0. 1 Conductivity cell, Epoxy body, Graphite sensor, w/3-wire Pt100, k = 1. 0 Code no. ECCONSEN89X ECCONSEN88X Note: Above Conductivity electrodes withstand up to 3 bar pressure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA COND 200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA COND 200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.