User manual ELECTRO-VOICE XI SYSTEM APPLICATIONS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ELECTRO-VOICE XI SYSTEM APPLICATIONS. We hope that this ELECTRO-VOICE XI SYSTEM APPLICATIONS user guide will be useful to you.


ELECTRO-VOICE XI SYSTEM APPLICATIONS : Download the complete user guide (5785 Ko)

Manual abstract: user guide ELECTRO-VOICE XI SYSTEM APPLICATIONS

Detailed instructions for use are in the User's Guide.

[. . . ] System Applications System Applications Xi Series 1. 1 2-Way Stereo Industrial Presentations, Side-Fill, Near-Fill Xi 1122 Xi 1122 Xi 1122 Xi 1122 Left Right L: 2 " R: 2 " L: 12 " R: 12 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1122/85 2 x P 1200 2 x NL4 long, 2 x NL4 short/long 1 Horizontal coverage: Average distance: Total amp. power: 2 x 120°-150° 20-25 meters 1, 600 Watts cont. * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 #1 Main Left In 2 Out 1 Main Right Lo L Out 2 Hi L Out 3 Lo R Out 4 Hi R Preset * #35 Comments Options For medium SPL's as stand alone. [. . . ] power: 3 x 100° 20-35 meters 4, 400 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left Center #2 Main Right Sub Comments Out 1 Lo L Lo R Out 2 Hi L Hi R Out 3 Lo C Out 4 Hi C Sub Preset * #47 #47(Out1&2), #48 (route Out4 to In2) Options Preset #47 is overlapped mode for maximum vertical directivity. SPL use 250 Hz X-Over setting. MF and HF horns could be rotated for vertical use. System Applications Xi Series 2. 5 2-Way LCR+Sub Small to medium venue, wide · Industrial Presentations L C R Left Center Right Sub L: 2 x 12" L:10" + 2" S: 2 x 18" S:2 x 18" C: 2 x 12" C:10" + 2" R: 2 x 12" R:10" + 2" Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 3 x Xi 2123, 4 x Xi 1191 4 x P 3000 3 x NL8 long, 3 x NL8 short 2 Horizontal coverage: Average distance: Total amp. power: 3 x 100° 20-25 meters 6, 300 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left Center #2 Main Right Sub Comments Out 1 Lo L Lo R Out 2 Hi L Hi R Out 3 Lo C Out 4 Hi C Sub Preset * #49 #49(Out1&2), #50 (route Out4 to In2) Options Preset #49 is overlapped mode for maximum vertical directivity. SPL use 250 Hz X-Over setting. MF and HF horns could be rotated for vertical use. P2000 may be used for Xi 2123. System Applications Xi Series 2. 6 2-Way Stereo+Sub+Side-Fill Very wide venue, Top 40 Bands Xi 1122 Xi 1122 Sub SF Left Right SF: 12" SF:2" L: 12 " L:10 " + 2 " S: 2 x 18" S:2 x 18" L: 12 " L:10 " + 2 " S: 2 x 18 " S:2 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 2 x Xi 2123, 2 x Xi 1122, 4 x Xi 2181 1 x P1200, 2 x P2000, 3 x P3000 3 x NL8 long, 7 x NL8 short 2 Horizontal coverage: Average distance: Total amp. power: 2 x 100° + 2 x 85° 25-30 + 20-25 meters 7, 650 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 #1 Main Left #2 Sub Comments In 2 Center Side Out 1 Lo L Sub Out 2 Hi L Out 3 Lo C Lo Si Options Out 4 Hi C Hi Si Preset * #49 #42(Out1), #35 (Out 3&4) Preset #49 is overlapped mode for maximum vertical directivity. SPL use 250 Hz X-Over setting. Xi 2123 could be driven 3-way (+ P1200 + Dx38) System Applications Xi Series 3. 1 3-Way Stereo Clubs/Smaller Venues XI 1152 XI 1152 Left Right Spare Spare L: 2 " R:2 " L: 15 " R:15 " L:2 x 18 " R:2 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1152/64, 2 x Xi 2181 1 x P 1200, 2 x P3000 2 Horizontal coverage: Average distance: Total amp. power: 2 x 60°-120° 20-25 meters 5, 500 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left #2 Main Right Comments Out 1 Lo L Lo R Out 2 Mid L Mid R Out 3 Hi L Hi R Options Out 4 Preset * #38 (change Out1 to 2181-see#42) #38 (change Out1 to 2181-see#42) Xi 1152 could be positioned for dedicated horizontal angles. System Applications Xi Series 3. 2 3-Way Stereo Clubs, Smaller Venues, Top 40 Bands Xi 1122 Xi 1122 Xi 1122 Xi 1122 Left Spare Spare Right L: 12" L:2" L: 12" L:2" L: 2 x 18 " L: 2 x 18 " L: 2 x 18 " L:2 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1122, 4 x XI 2181 4 x P 3000 2 x NL4 long/short, 2 x NL8 long/short 2 Horizontal coverage: Average distance: Total amp. power: 2 x 100°-160° 20-25 meters 6, 400 Watts (cont. ) * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left #2 Main Right Comments Out 1 Lo L Lo R Out 2 Mid L Mid R Out 3 Hi L Hi R Options Out 4 Preset * #36 (change Out1 to 2181-see#42) #36 (change Out1 to 2181-see#42) Xi 1122 could be positioned for dedicated horizontal angles P3000 can be used through out. System Applications Xi Series 3. 3 3-Way Stereo Clubs, Smaller Venues, Top 40 Bands Xi 1152 Xi 1152 Xi 1152 Xi 1152 L: 15" L:2" R: 15" R:2" L: 2 x 18" L:2 x 18" R: 2 x 18" R:2 x 18" Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1152/64, 4 x Xi 2181 4 x P 3000 2 x NL4 long/short, 2 x NL8 long/short 2 Horizontal coverage: Average distance: Total amp. power: 2 x 100°-120° 20-25 meters 7, 900 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left #2 Main Right Comments Out 1 Lo L Lo R Out 2 Mid L Mid R Out 3 Hi L Hi R Options Out 4 Preset * #38 (change Out1 to 2181-see#42) #38 (change Out1 to 2181-see#42) Xi 1152 could be positioned for dedicated horizontal angles P3000 can be used through out. System Applications Xi Series 3. 4 3-Way Stereo Clubs, Top 40 Bands Left Spare Right Spare L: 2 x 12" L:10" + 2" R: 2 x 12" R:10" + 2" L: 2 x 18 " L:2 x 18 " R: 2 x 18 " R:2 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 2 x Xi 2123, 4 x Xi 2181 2 x P2000, 2 x P3000 4 x NL8 long 2 Horizontal coverage: Average distance: Total amp. [. . . ] low noise 3-stage fans low noise 3-stage fans low noise 3-stage fans 88. 1 mm 132. 5 mm 132. 5 mm 483 mm 483 mm 483 mm 426 mm 426 mm 426 mm 17. 0 kg 27. 0 kg 28. 0 kg DX38 Digital Sound System Processor S p e c i f i c at i o n s Inputs Outputs A/D Converter D/AConverter Data Format Dynamic Range Network Filter EQs Maximum Delay Time Size (W x H x D) Net weight 2 x 2 XLRIN balanced (female / male) 4 XLROUTbalanced 24 bit, Sigma-Delta, 128x Oversampling, linear phase 24 bit, Sigma-Delta, 128x Oversampling 48 bit Processing >115 dB 6, 12, 18, 2 dB/Oct. slope; Butterworth, Bessel, Linkwitz-Reiley 26 Parametric Equaliser 2. 7 sec 483 mm x 43. 6 mm x 374 mm (19", 1 U) 5. 0 kg Telex EVI Audio GmbH Hirschberger Ring 45 · D- 94315 Straubing · Germany Tel: +49 (0)94 21-7 060 · Fax: +4 9 (0)94 21-7062 65 · www. electro-voice. de [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRO-VOICE XI SYSTEM APPLICATIONS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRO-VOICE XI SYSTEM APPLICATIONS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.