User manual DANBY SAC10504D

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DANBY SAC10504D. We hope that this DANBY SAC10504D user guide will be useful to you.


DANBY SAC10504D : Download the complete user guide (2602 Ko)

Manual abstract: user guide DANBY SAC10504D

Detailed instructions for use are in the User's Guide.

[. . . ] · Installation must be done by the manufacturer or service agent or a similar qualified person in order to avoid a hazard. WHEN INSTALLING Do not install the air conditioner where there's combustible gas. Do not install the outdoor unit where there's the risk of dropping such as on high outer wall or outside of the terrace. Earth the ground conductor and do not connect it to the gas pipe, water pipe or telephone wire. Contact the service center if the air conditioner is under water. REGARDING POWER SOURCE Do not pull the electric wire or touch the power plug with the wet hands. Install the switch and circuit breaker only for air conditioner. Use the rated current fuse. Do not bend the electric wire by force or weigh down the air conditioner not to be out of order. Use the power source with separate wiring only for air conditioner. If the power plug is damaged, replace it by the manufacturer or qualified personal to avoid the risk. E-3 ENGLISH Register your product at www. samsung. com/global/register WARNING DURING OPERATION Users of this product are cautioned not to attempt repair of this product at their own discretion. Instead, they are requested to directly contact a designated service center or the outlet at which the product was purchased. Never spill any kind of liquid into the unit. Should this happen, unplug or main switch off the unit and contact an authorized service center. Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury. Keep children away from the unit. Do not place any obstacles in front of the unit. [. . . ] Do not place clothing or other materials over it. If the wireless remote control is not used for a long time, remove the batteries. (If applicable) When using a wireless remote control, the distance should not be more than 7m(23ft) from the air conditioner. (If applicable) Do not place any materials so that children cannot step on it. Do not connect the electric heater to the air conditioner or repair it with your discretion. E-4 WARNING DISPOSING THE UNIT Before throwing out the device, it is necessary to pull back the battery cells and get rid of them safely for recycling reasons. When you need to dispose of the unit, consult your dealer. If pipes are removed incorrectly, refrigerant may blow out and come into contact with your skin, causing injury. Releasing refrigerant into the atmosphere also damages the environments. Please recycle or dispose of the packaging material for this product in an environmentally responsible manner. CAUTION WHEN INSTALLING Install the air conditioner avoiding direct sunlight or heater, especially water. Install the outdoor unit so as to let the discharged air out properly. Avoid a place that may disturb your neighbor by noise. Install the drain hose to let the water run safely and correctly. E-5 ENGLISH CAUTION REGARDING POWER SOURCE Disconnect the circuit breaker when you don't use the air conditioner for a long time to save energy. Contact the service center or manufacturer if you want to repair the air conditioner. Contact the service center after turning off the air conditioner if strange noise is heard, burning smell or smoke blows. DURING OPERATION Do not open the front grille during operation. Avoid cold and hot air reaching to person, pet or a plant directly for a long time. Avoid the water from getting into the air conditioner. Do not use the air conditioner for a long time in a closed room or in a place where there's a baby or an old person. Do not step on the air conditioner or put heavy object on it. Do not drink the water from the air conditioner. E-6 CAUTION DURING OPERATION Do not touch the pipes connected to the air conditioner. Do not use the air conditioner to maintain the machine, food, pet, plant or cosmetics. Do not give excessive shock to the air conditioner. OTHERS Be sure that the air filter not to be exposed to direct sunlight. The appliance is not intended for use by young children or infirm persons without supervision: Young children should be supervised to ensure that they do not play with the appliance. Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency. Turn off the air conditioner and if the fan stops operating, clean the air conditioner. Do not clean the air conditioner by spraying water directly or with benzene, thinner or alcohol. The surface of the heat exchanger is sharp, so be careful of it when cleaning. Clean the air filter every 2 weeks. Be sure to insert the air filter. E-7 ENGLISH View of the Indoor Unit The figures are shown in this instruction may differ from yours depending on the model. Indoor Unit 1 way & Slim 1 way cassette 2 way cassette Air flow blade Air inlet Air flow blades(outlet) Air inlet Air filter(inside the grille) Timer indicator Remote control sensor - Heat Pump Models : On/Off indicator(Green) & Removing frost indicator(Red) - Cooling Only Models : On/Off indicator Fan indicator Filter sign indicator Filter Sign indicator Fan indicator Timer indicator On/Off indicator On/Off button Remote control sensor Indoor Unit 4 way & mini 4 way cassette Type A Timer indicator Remote control sensor Filter Sign indicator On/Off button On/Off indicator Fan indicator Removing frost indicator Type B Air flow blades (outlet) Air inlet Timer indicator Air filter (under the grille) Removing frost indicator On/Off indicator On/Off button Remote control sensor Filter Sign indicator Fan indicator Type C Filter Sign indicator Fan indicator Timer indicator Removing frost indicator On/Off indicator On/Off button Remote control sensor E-8 Periodical Checks Type Description Clean the air filter Clean the condensate drain pan (2) Monthly (1) Every 4 months Once a year Indoor unit Thoroughly clean the heat exchanger (2) Clean the condensate drain pipe (2) Replace the remote control batteries Clean the heat exchanger on the outside of the unit (2) Clean the heat exchanger on the inside of the unit (2) Clean the electric components with jets of air (2) Outdoor unit Verify that all the electric components are firmly tightened (2) Clean the fan (2) Verify that all the fan assembly is firmly tightened (2) Clean the condensate drain pan (2) The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner. The frequency of these operations varies according to the characteristics of the area, the amount of dust, etc. (1) The described operations should be performed more frequently if the area of installation is very dusty. For more detailed information, see the Installation Manual. Protections enabled by the Unit control system Type of protection Protection against cold air Defrost cycle Anti-frost protection of internal battery Delayed start of compressor CAUTION Description The internal fan is off The internal fan is off The compressor is off The start of the compressor is delayed. Operation Heating on heat pump Heating on heat pump Cooling During operation Cooling or Heating on heat pump At start-up or during the selection of the operating mode When it enables During operation During operation If the air conditioner is operating in heat pump mode, it performs several defrost cycles in order to remove the frost that may have deposited on the outdoor unit (at low temperatures). You must give attention when disassembling the front grille and must check the safety clips have been installed. If you do not check them, the front grille will drop suddenly and you will be hurt. CAUTION 2 Remove the front grille. 2-2 Open the front grille about 45° and pull it forward. 3 4 Pull out the air filters. In case of serious dust accumulation, put the air filter in warm detergent water and shake it vertically. Note When you have installed the Bio-Pure filter, do not allow any liquids to contact the filter. It may lose its properties. 5 6 7 8 he design and shape are subject to T change according to the model. After washing, allow them to dry throughly in an area protected from sunlight. Note You can use all 2 points of the indoor unit for installing the front grille and the safety clips depending on your requirement. Note Wired Remote Control After cleaning the air conditioner, press the Filter Reset button. Wireless Remote Control (TypeB) Wireless Remote Control (TypeA) E-14 Solving Common Problems Before contacting the after-sales service, perform the following simple checks. Explanation/Solution Check if power is on and operate the air conditioner again. Check if you pressed the button after selecting time. The temperature is not adjusted. The cool(warm) air does not come out from the air conditioner. The fan speed is not adjusted. [. . . ] The cool(warm) air does not come out from the air conditioner. The fan speed is not adjusted. The remote controller does not operate. The wired remote controller does not operate. The Timer is not set. The air conditioner does not turn on Check if you set the wired remote controller for group control. Odor is permeated in the room during operation The indoor unit indicator flashes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DANBY SAC10504D




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DANBY SAC10504D will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.