User manual DANBY DKC445BLS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DANBY DKC445BLS. We hope that this DANBY DKC445BLS user guide will be useful to you.


DANBY DKC445BLS : Download the complete user guide (312 Ko)

Manual abstract: user guide DANBY DKC445BLS

Detailed instructions for use are in the User's Guide.

[. . . ] Keg Cooler The model number can be found on the serial plate located on the back panel of the unit. All repair parts available for purchase or special order when you visit your nearest service depot. To request service and/or the location of the service depot nearest you, call the TOLL FREE NUMBER. When requesting service or ordering parts, always provide the following information: · Product Type · Model Number · Part Description Model · Modèle· Modelo DKC445BL For service, contact your nearest service depot or call: 1-800-26- Danby (1-800-263-2629) to recommend a depot in your area. Glacière de bière en fût Le numéro du modèle se trouve sur la plaque d'identification située sur le panneau arrière de l'appareil. En cas de réparation, veuillez contacter votre service après-vente le plus près ou communiquez au: 1-800-26- Danby (1-800-263-2629) pour connaître le service après-vente le plus proche. Il est possible d'acheter les pièces de rechange ou de les obtenir par commande spéciale en vous rendant à votre service après-vente le plus proche. [. . . ] Installation of the Keg Coupler: IMPORTANT NOTICE; Make sure the black pull handle of the keg coupler is in the "upward" (closed) position before installing on the beer keg. 9 Insert the keg coupler into the locking neck of the beer keg and apply a 1/4 turn clockwise to lock into position. Installation of the CO2 Air Line Hose to the Keg Coupler: Attach the open end of the (red) air line hose to the hose barb connection on the keg coupler. Secure hose by using the remaining (self locking) plastic snap on clamp provided. Installation of the Beer Line Hose to the Keg Coupler: IMPORTANT NOTICE: The black rubber washer (provided) must be installed inside the wing nut before connecting the beer line to the keg coupler. Remove the black rubber protective cap located on top of the keg coupler and screw the wing nut (with rubber washer) onto the keg coupler. Making the connection between the Keg Coupler and Beer Keg: Before making (opening) connection between the keg coupler and beer keg, make sure the beer tower faucet is in the closed position. (faucet handle straight back) To engage the tank connection, pull the keg coupler handle out and push down until it locks into position. Listen for positive "click" of the pull handle in the final downward position. Opening the CO2 Cylinder Main Valve: Before opening the main valve located on top of the CO2 cylinder. Make sure the "secondary" shut-off valve located on the lower stem pipe of the regulator is in the "closed" position. 11 NOTE: When the secondary valve (handle) is positioned "Horizontal" (east/west) the valve is closed. 1 2 When the secondary valve (handle) is positioned "Vertical" (north/south) the valve is open. To open the main CO2 cylinder valve, (slowly) turn the main valve counter clockwise until fully open. Adjusting the CO2 Regulator: There are two pressure gauges on the CO2 regulator. 12 The upper gauge #1 monitors "LOW" (internal keg) pressure and must be adjusted to the correct operating pressure of 10~12psi/lbs. The lower gauge #2 monitors "HIGH" (CO2 cylinder) pressure and is not adjustable. The high pressure gauge also acts as a fuel gauge to let you know when the C02 cylinder needs re-filling. IMPORTANT: The internal operating pressure of the beer keg should be adjusted and maintained between 10 ~ 12psi/lbs. To adjust the "low" pressure gauge; · Using an adjustable wrench, release the adjustment lock nut # 3. 12 · Using a flat screwdriver, turn the regulator adjustment screw # 4 See Fig. 12 Clockwise rotation of the adjustment screw will increase low pressure. Counter clockwise rotation of the adjustment screw will decrease low pressure · When the required operating pressure is attained retighten the adjustment lock nut # 3. [. . . ] #445-7703 #445-5571 OPTIONAL ACCESSORIES FOR ALL REFRIGERATOR: Description Crisper Drawer Crisper Cover Additional Wire Cantilever Shelf Part No. #452. 1C #452. 28 #452. 33 For more details on purchasing any of the above listed accessories, please contact our after sales service department at 1-800-26-DANBY (1-800-263-2629). ADDITIONAL INFORMATION ON CO2 Afully charged (5lb). CO2 cylinder will service (approx. ): Quantity. 20 30 Liter Kegs (1/4 Barrels) 25 20 Liter Kegs (1/6 Barrels) For the location of a CO2 supplier in your area, (re-fills) please look in your "Yellow Page" telephone directory under "OXYGEN" suppliers. 12 LIMITED PRODUCT WARRANTY This quality product is warranted to be free from manufacturer's defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby or by an authorized distributor of Danby, and is non-transferable. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DANBY DKC445BLS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DANBY DKC445BLS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.