User manual BIOPTECHS HINGEDPERFUSION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BIOPTECHS HINGEDPERFUSION. We hope that this BIOPTECHS HINGEDPERFUSION user guide will be useful to you.


BIOPTECHS HINGEDPERFUSION : Download the complete user guide (235 Ko)

Manual abstract: user guide BIOPTECHS HINGEDPERFUSION

Detailed instructions for use are in the User's Guide.

[. . . ] Delta T Hinged Perfusion Adapter Set Instructions The Bioptechs Hinged Perfusion Supports provide Delta T users with a convenient and inexpensive method of supporting perfusion needles in the culture dish. [. . . ] Additional supports can be added to hold gas jets, pH probes, cooling apparatus, or other items which do not require critical positioning. Benefits: · · · · · · Needles compatible with 1/16" tubing User adjustable friction for reliable positioning Repeatable positioning, flips in and out to replace dishes Adjustable pick-up tube to control level of media in dish* Perfusion assembly translates with the stage adapter and dish Eliminates the need for expensive micromanipulators for low precision positioning *Bioptechs recommends the use of the Delta T Micro-Perfusion Pump for closely regulated perfusion. Instructions: Press fit the 1/8" ends of the hinge adapter into the stage adapter. Adjust the tension of the hinge with the 5/64" Allen driver provided. Press tubing onto the 14 gauge needles and attach to fluid irrigation and aspiration as noted below. Continual Delta TC3 Perfusion with the Delta T Micro-Perfusion Pump: The Delta T Micro-Perfusion Pump is shipped with dual channel tubing. When the tubing pair is stretched around the rollers on the pump, the tube with the black band will have a slightly smaller ID yielding a slower fluid transport capability. Attach the supply line from your media to the barb on the input side of the black band pump tubing and another tube from the output side of this tube to the selected irrigation port of the dish. Attach tubing from the aspiration port of the dish to the input side of the other pump tube and a line from the output side of this pump tube to a waste container. [. . . ] Note: Please refer to the back of this page for an instructional diagram. 3560 Beck Road · Butler, PA 16002 · Voice: 724-282-7145 · Fax: 724-282-0745 · E-mail: info@bioptechs. com · Web: www. bioptechs. com [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIOPTECHS HINGEDPERFUSION




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BIOPTECHS HINGEDPERFUSION will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.