User manual AUSTRALIAN MONITOR AMIS120P

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AUSTRALIAN MONITOR AMIS120P. We hope that this AUSTRALIAN MONITOR AMIS120P user guide will be useful to you.


AUSTRALIAN MONITOR AMIS120P : Download the complete user guide (233 Ko)

You may also download the following manuals related to this product:

   AUSTRALIAN MONITOR AMIS120P (149 ko)
   AUSTRALIAN MONITOR AMIS120P BROCHURE (340 ko)
   AUSTRALIAN MONITOR AMIS120P DATASHEET (453 ko)

Manual abstract: user guide AUSTRALIAN MONITOR AMIS120P

Detailed instructions for use are in the User's Guide.

[. . . ] The AMIS120P features a line level input (with parallel output) and is normally used with mixers, mixer amplifiers or other power amplifiers. The AMIS120P also features 24 volt DC operation. Front Panel Features Power Switch The black rocker switch on the right hand side of the front panel is used to switch the amplifier on and off. When the amplifier is connected to an appropriate AC power source and is switched on, the blue power LED will illuminate. In DC operation mode, the amplifier is always on and the blue power LED will always be illuminated. `On' LED The blue "On" LED above the power switch will illuminate when the amplifier is connected to mains power and is switched on, or when the amplifier is connected to DC power. Signal LED The green "Signal" LED located next to the `On' LED indicates that the AMIS120P is receiving audio signal via its line level input. [. . . ] When both outputs are used simultanously, ensure that neither output is loaded to maximum. Level Control Located to the left of the XLR input/output is a recessed screwdriver adjustable level control. The level control is an input attenuation control normally used to match the amplifier to a wide variety of input signals. In essence, the amplifier is designed to receive a 700mv input signal however, the level control can be used to increase the level for lower signals or decrease the level for higher input signals. In normal use, the level control is used as a `set and forget' master level control for the amplifier. XLR Audio Input and Parallel Output The AMIS120P includes both male and female 3 pin XLR connectors. While the female is normally used as the input to the amplifier, both XLR's are connected in parallel so either will work. When signal is connected to one XLR, the other XLR becomes a line level output allowing the input signal to be distributed (split) to other amplifiers. In some projects, the same input may be looped through to multiple amplifiers using this method. Up to 6 amplifiers can be looped together without any noticeable loss in level. A distribution amplifier should be used when more than 6 amplifiers need to be looped. Pin 3: Cold, -, Negative Fuse Sizes Mains, 115VAC: 8 Amperes Slow Blow. Notes: The DC fuse is located on the circuit board. This is a feature of the AMIS series amplifier, which is equipped with a current limiting circuit preventing excessive DC current, thus eliminating the risk of blowing high tensions fuses. In the unlikely event that the DC fuse actuates, the output transistors should be checked, as it is probable that the amplifier has been subjected to very extreme conditions. Important Safety Information 1. Save the carton and packing material even if the equipment has arrived in good condition. Should you ever need to ship the unit, use only the original factory packing. Do not spill water or other liquids into or on the unit, or operate the unit while standing in liquid. Make sure power outlets conform to the power requirements listed on the back of the unit. The power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit from the appliance. Always operate the unit with the AC ground wire connected to the electrical system ground. Precautions should be taken so that the means of grounding of a piece of equipment is not defeated. Mains voltage must be correct and the same as that printed on the rear of the unit. [. . . ] Never connect a "hot" (red) output to ground or to another "hot" (red) output!The power cord of equipment should be unplugged from the outlet when left unused for a long period of time. Service Information Equipment should be serviced by qualified service personnel when: A. The equipment does not appear to operate normally, or exhibits a marked change in performance E. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AUSTRALIAN MONITOR AMIS120P




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AUSTRALIAN MONITOR AMIS120P will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.