User manual AEG AGN 2400 B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG AGN 2400 B. We hope that this AEG AGN 2400 B user guide will be useful to you.


AEG AGN 2400 B : Download the complete user guide (2500 Ko)

Manual abstract: user guide AEG AGN 2400 B

Detailed instructions for use are in the User's Guide.

[. . . ] PORTABLE GENERATOR SET Original Instructions AGN2400B circuit breaker carburetor drain screw Fig. 2 air filter fuel valve recoil starter grip oil cap/ dipstick Fig. 3 fuel tank fuel level gauge fuel cap oil fill hole oil cap/ dipstick Fig. 6 to start (choke closed) ON OFF choke lever ON OFF RUN CHOKE fuel valve to run (choke open) Fig. [. . . ] Never use a generator inside homes, garages, crawlspaces, or other partly enclosed areas. Using a fan or opening windows and doors does NOT supply enough fresh air. n ONLY use a generator outdoors and far away from open windows, doors, and vents. ALWAYS use a battery-powered or battery-backup CO alarm in the home. n NOTE: Non-detergent or 2-stroke engine oils will damage the engine and should not be used. n n n n If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. You could have carbon monoxide poisoning. n Unscrew the oil cap/dipstick and remove. Oil level should fall within the level indicator area on the dipstick. If level is low, add engine oil until the fluid level rises to the upper portion of the level indicator area on the dipstick. Replace and secure the oil cap/dipstick. DANGER: Failure to properly ground generator can result in electrocution, especially if the generator is equipped with a wheel kit. Remember that a careless fraction of a second is sufficient to inflict serious injury. CHECKING/ADDING fUEL See Figure 5. NOTE: Always use unleaded gasoline with a pump octane rating of 86 or higher. Never use old, stale, or contaminated unleaded fuel, and do not use an oil/gas mixture. Do not allow dirt or water into the fuel tank. n 9 English UsING fUEL sTABILIsER Fuel gets old, oxidizes, and breaks down over time. Adding a fuel stabiliser extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system. Follow fuel stabiliser manufacturer's directions for correct ratio of stabiliser to fuel. n n n Add stabiliser to fuel tank, then fill with unleaded fuel following previous instructions. NOTE: Fuel stabiliser and unleaded fuel can be mixed prior to filling the tank by using a gas can or other approved fuel container and shaking gently to combine. Start and run the engine for at least 5 minutes to allow stabiliser to treat the entire fuel system. NOTE: Some conventional petrol are blended with alcohol or an ether compound. This type of petrol is collectively referred to as oxygenated fuel; in Australia known as Ethanol. The use of ethanol fuel, or fuels containing ethanol is not recommended for this product. CAUTION: On a level surface with the engine off, check the oil level before each use of the generator. (later on this page) n Switch the AC circuit breakers to the ON ( I ) position. DC OpERATION The DC terminals may ONLY be used for charging 12 volt automotive type batteries. OXyGENATED fUELs DO NOT UsE E85 fUEL. IT WILL VOID yOUR WARRANTy. Connecting the battery cables: Before connecting the battery charging cables to a battery that is installed in a vehicle, disconnect the vehicle ground battery cable from the battery negative (-) terminal. [. . . ] However, if the knocking or pinging occurs under normal load at a steady engine speed, the problem may be with the brand of unleaded fuel being used. Switch to a different brand of unleaded fuel, making sure that the octane rating is 86 or higher. If problem continues, contact your nearest authorized service center. If problem persists after trying the above solutions, contact your nearest authorized service center for assistance. The following symptoms may indicate problems that will affect the emissions level of the unit: Hard starting or stalling after starting Rough idle Misfiring or backfiring under load Afterburning (backfiring) Black exhaust smoke or high fuel consumption n n n n n If you encounter any of these symptoms, have the unit inspected and repaired by the nearest authorized service center. 14 WIRING DIAGRAM - AGN2400B English 15 LImITED WARRANTy TTI warrants this outdoor product to be free of defects in material and workmanship for 24 months from the date of purchase by the original purchaser, subject to the limitations below. This warranty is only applicable where the product is used for personal and non-commercial purposes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG AGN 2400 B




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG AGN 2400 B will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.