User manual 3R SYSTEM WCL-03CU TOTAL
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual 3R SYSTEM WCL-03CU TOTAL. We hope that this 3R SYSTEM WCL-03CU TOTAL user guide will be useful to you.
Manual abstract: user guide 3R SYSTEM WCL-03CU TOTAL
Detailed instructions for use are in the User's Guide.
[. . . ] · Take care not to be scratched with sharp edges while installing this product to your system. · Tenga cuidado de no usar herramientas afiladas o puntiagudas mientras instala este producto en su equipo. · This product is intended for the use with a personal computer only. [. . . ] · During the period of one year from the date of purchase, 3R SYSTEM will repair or replace defective parts at its expense, on condition that the product has been used in a normal environment and conditions specified above. 3R SYSTEM is not liable for the damage for any other computer components. ·3R SYSTEM reparará o reemplazará las partes defectuosas sin coste alguno, por el período de un año desde la fecha de compra, siempre y cuando el producto haya sido usado en un ambiente normal y y en las condiciones especificadas más arriba. 3R SYSTEM no se hace responsable del daño de ningún otro componente de su equipo. · It is prohibited to duplicate or copy this manual without permission from 3R SYSTEM. · Prohibido duplicar o copiar este manual sin permiso de 3R SYSTEM. · For the latest information on our products, please visit our website. · Para las últimas noticias de nuestros productos, por favor, visítenos en nuestra página web: www. 3rsystem. co. kr
I-2. WCL02, WCL03 INFORMATION
WCL02-90Cu
155 mm 105 mm
WCL03-90Cu
80 mm
WCL02-120Cu
145 mm 125 mm
WCL03-120Cu
80 mm
INSTALLATION SPACE
80mm size .
120mm size .
AIR FLOW
PERFORMANCE
200 W (Max. ) Fan 4, 000 RPM - 200W Fan 2, 000 RPM - 170W DC12V 4W
1200cc/Min (Head) 650mm
200W (Max. ) Fan 4, 000 RPM - 200W Fan 2, 000 RPM - 170W DC12V 4W
600 cc/Min (Head) 350mm
230 W (Max. ) Fan 3, 000 RPM - 230W Fan 2, 000 RPM - 190W DC12V 4W
1200cc/Min (Head) 650mm
230 W (Max. ) Fan 3, 000 RPM - 230W Fan 2, 000 RPM - 190W DC12V 4W
600 cc/Min (Head) 350mm
PUMP
CPU
INTEL : Socket 478 , Socket 370 - P4 3. 4C , Presscott 3. 4E , P3 , CELERON AMD : Socket A , Socket 462 , Socket 754 - BARTON 3200 , DURON SERIES CLIP Option Parts : AMD64 3200 , Xeon (Socket 603) , LGA775 (Socket T) - 2004. SEP
III-1. After unpacking, please check the contents of a box and be sure everything is included.
1
2
3
MM 90 MM
No.
Part Name
WCL03-120Cu Set
Description
High Performance Heat-exchanger (120mm) Water Tank Radiator Cooling FAN (120mm x 120mm x 25t) Magnet Pump (4W) Aluminum Water Block with Cu Plate High performance Heat-exchanger (90mm) Water Tank Radiator Cooling FAN (92mm x 92mm x 25t) Magnet Pump (4W) Aluminum Water Block with Cu Plate for AMD CPU Motherboard for AMD 64 CPU Motherboard for INTEL P-4 CPU Motherboard Thermal Grease for Fixing the Radiator Radiator Fan Speed Control Quick Installation Guide
Qty
90Cu
120Cu
1
1 set
2
WCL03-90Cu Set
1 set
3
AMD Clip Set AMD 64 Clip Set (Option) P-4 Clip Set Thermal Grease Bolt Fan Controller Quick Installation Guide
1 set 1 set 1 set 4 sets 1 pc 1 pc
4
III-2. WCL03 INFORMATION
Basic Coolant Flow [ )
WATER TANK
PUMP UNIT
RADIATOR
CPU WATER BLOCK CPU
FAN (AIR)
Water Block Inatallation Direction [ ]
III-3. Be sure there is no trace of leak on tubes and fittings
WCL03-120Cu
WCL03-90Cu
From : PC Power DC 12V
ON
ON
From : PC Power DC 12V
STEP 2 : WCL03 INSTALLATION
- WATER BLOCK / PUMP UNIT FIXING
1. .
Parts
1
2
3
4
5
Tension Control
Apply Grease 1. AMD CPU CPU .
Please pay special attention while installing a water block / pump unit on AMD CPU since the CPU core is located off-center on the plate and incorrect installation will greatly lower the cooling performance. Be sure the unit is placed in the right Direction and a correct clip is used in a designated place.
CLIP INSTALLATION DIRECTION
W/O FOAM ATTACHED W/ FOAM ATTACHED
Water block Direction
1. Clip Tension Control
FOAM
TENSION CONTROL
STEP 3 : WCL03 INSTALLATION
- Radiator Bolt Fixing Parts Parts
STEP 4 : WCL03 INSTALLATION
- Radiator & Pump Unit Cable Connection
1. Pump Unit 1-pin Cable CPU Fan Terminal With PC Power ON , Check Water Flow for 2~3 Minutes (Check Tube's Bend ) 2-3 Noise Control ( Use Fan Controller )
WCL02-90Cu
WCL02-120Cu
. .
Air flow WCL02-120Cu
4
From : PC Power DC 12V
1
Air flow WCL02-90Cu
1 2 3 2
CHECK LIST
1. [. . . ] : W00XA1-01850
120 Fan (3000 rpm) (1ea) Fan Controller (1 ea) Fan bolt (4 ea)
3
11
VGA Water Block
No. : W00XA1-01780
VGA Water Block (1ea) VGA Clip (1set) Thermal Grease (1ea) Tube Fitting (2 ea)
Silicone Tube
No. : W00XA1-01860
Silicone Tube ( 2M )
4
12
External 120mm Radiator
No. [. . . ]