Detailed instructions for use are in the User's Guide.
[. . . ] H3C WX5002 Access Controller Installation Manual
Hangzhou H3C Technologies Co. , Ltd.
Manual Version: T2-080410-20090605-C-1. 02
Copyright © 2007-2009, Hangzhou H3C Technologies Co. , Ltd. and its licensors H3C Technologies Co. , Ltd. , a subsidiary of 3Com Corporation.
All Rights Reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co. , Ltd.
Trademarks
H3C, , Aolynk, , H3Care, , TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V2G, VnG, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co. , Ltd. All other trademarks that may be mentioned in this manual are the property of their respective owners.
Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
About This Manual
Organization
H3C WX5002 Access Controller Installation Manual is organized as follows: Chapter 1 Product Overview Contents Introduces the features and appearance of the H3C WX5002 access controller. [. . . ] After you type the correct password, the system enters the BootWare main menu:
==================<EXTEND-BOOTWARE MENU>=================== | <1> Boot System | <2> Enter Serial SubMenu | <3> Enter Ethernet SubMenu | <4> File Control | <5> Modify BootWare Password | <6> Ignore System Configuration | <7> BootWare Operation Menu | <8> Clear Super Password | <0> Reboot | | | | | | | | |
=========================================================== Enter your choice (0-8):
The menu is described in the following table. Table 5-1 BootWare main menu Menu item <1> Boot System <2> Enter Serial SubMenu <3> Enter Ethernet SubMenu <4> File Control <5> Modify BootWare Password <6> Ignore System Configuration <7> BootWare Operation Menu <8> Clear Super Password <0> Reboot Boot the system Enter the serial submenu. Boot the system with the system configuration ignored BootWare operation submenu. Description
BootWare Submenus
Serial submenu
You can upgrade application programs, change the serial interface baud rate and so on through this submenu. Select 2 in the BootWare main menu to enter the serial submenu.
======================<SERIAL SUB-MENU>====================== | <1> Download Application Program To SDRAM And Run | <2> Update Main Application File | <3> Update Backup Application File | <4> Update Secure Application File | | | |
5-4
| <5> Modify Serial Interface Parameter | <0> Exit To Main Menu
| |
============================================================= Enter your choice (0-5):
Items in this submenu are described in the following table. Table 5-2 BootWare serial submenu Menu item <1> Download Application Program To SDRAM And Run <2> Update Main Application File <3> Update Backup Application File <4> Update Secure Application File <5> Modify Serial Interface Parameter <0> Exit To Main Menu Description Download an application program to SDRAM and run the program. Return to the BootWare main menu.
Ethernet submenu
Select 3 in the BootWare main menu to enter the Ethernet submenu. The system displays:
====================<ETHERNET SUB-MENU>====================== | <1> Download Application Program To SDRAM And Run | <2> Update Main Application File | <3> Update Backup Application File | <4> Update Secure Application File | <5> Change Ethernet Parameter | <0> Exit To Main Menu | < Ensure The Parameter Be Modified Before Downloading!> | | | | | | |
============================================================= Enter your choice (0-5):
Items in the Ethernet submenu are described in the following table. Table 5-3 Ethernet submenu Menu item <1> Download Application Program To SDRAM And Run <2> Update Main Application File <3> Update Backup Application File <4> Update Secure Application File <5> Change Ethernet Parameter <0> Exit To Main Menu Description Download an application program to SDRAM and run the program. Return to the BootWare main menu.
5-5
File control submenu
Select 4 in the BootWare main menu to enter the file control submenu. You can view the application file types, modify file names, and delete files through the submenu.
========================<FILE CONTROL>======================= | <1> Display All File(s) | <2> Set Application File Type | <3> Delete File | <0> Exit To Main Menu | | | |
============================================================= Enter your choice (0-3):
Items in this submenu are described in the following table. Table 5-4 File control submenu Menu item <1> Display All File(s) <2> Set Application File Type <3> Delete File <0> Exit To Main Menu Display all files. Description
BootWare operation submenu
Select 7 in the BootWare main menu to enter the BootWare operation submenu:
=====================<BOOTWARE OPERATION>==================== | <1> Backup Full BootWare | <2> Restore Full BootWare | <3> Update Full BootWare With XModem | <4> Update Extend BootWare With XModem | <5> Update Basic BootWare With XModem | <0> Exit To Main Menu | | | | | |
============================================================= Enter your choice (0-5):
Items in this submenu are described in the following table. Table 5-5 BootWare operation submenu Menu item <1> Backup Full BootWare <2> Restore Full BootWare <3> Update Full BootWare With XModem <4> Update Extend BootWare With XModem <5> Update Basic BootWare With XModem <0> Exit To Main Menu Description Back up the full BootWare. Return to the BootWare main menu.
5-6
Upgrading BootWare Through a Serial Interface
Use XMODEM to upgrade BootWare through a serial interface.
Modifying Serial Interface Parameters
Sometimes, we need to make the serial interface baud rate higher to save upgrading time or make it lower to guarantee transmission reliability. Enter the BootWare main menu and select 2 to enter the serial interface submenu, and then select 5 in the submenu to modify the baud rate. The system displays the following:
========================<BAUDRATE SET>======================= |Note: | Change The HyperTerminal's Baudrate Accordingly, Press 'Enter' to exit with things untouched. | |
|--------------------<Baudrate Avaliable>-------------------| | <1> 9600(Default) | <2> 19200 | <3> 38400 | <4> 57600 | <5> 115200 | <0> Exit | | | | | |
============================================================= Enter Your Choice (0-5):
Select a proper baud rate. For example, select 5 for a baud rate of 115, 200 bps and the system displays the following information:
Download speed is 115200 bps. Change the terminal's speed to 115200 bps, and select XMODEM protocol. Press 'Enter' key when ready.
At this time, the baud rate of the AC serial interface is modified to 115, 200 bps, while that of the terminal is still 9, 600 bps. [. . . ] If the above-mentioned items ruled out, the problem may lie in the console cable or the settings of the terminal (such as HyperTerminal) parameters. Please perform the corresponding check.
Troubleshooting when illegible characters are displayed on the terminal
If illegible characters are displayed at the console terminal, the problem probably lies in the parameter settings on the terminal (such as HyperTerminal). Verify the following terminal parameter (such as HyperTerminal) settings:
6-1
Bits per second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow control: None Emulation: VT100.
6-2
Table of Contents
Appendix A Obtaining Support for your Product····················································································· A-1 Register Your Product···························································································································· A-1 Purchase Value-Added Services ··········································································································· A-1 Troubleshoot Online······························································································································· A-1 Access Software Downloads ················································································································· A-1 Telephone Technical Support and Repair ····························································································· A-1 Contact Us ············································································································································· A-2
i
Appendix A Obtaining Support for your Product
Register Your Product
Warranty and other service benefits start from the date of purchase, so it is important to register your product quickly to ensure you get full use of the warranty and other service benefits available to you. Warranty and other service benefits are enabled through product registration. [. . . ]