User manual 3COM SS3 BASELINE 100/1000 SW 6-PORT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual 3COM SS3 BASELINE 100/1000 SW 6-PORT. We hope that this 3COM SS3 BASELINE 100/1000 SW 6-PORT user guide will be useful to you.


3COM SS3 BASELINE 100/1000 SW 6-PORT : Download the complete user guide (1696 Ko)

Manual abstract: user guide 3COM SS3 BASELINE 100/1000 SW 6-PORT

Detailed instructions for use are in the User's Guide.

[. . . ] SuperStack® 3 Baseline 10/100/1000 Switch 6-Port 10BASE-T/100BASE-TX/1000BASE-T (3C16468) User Guide DUA1646-8AAA02 INTRODUCTION The SuperStack® 3 Baseline 10/100/1000 Switch 6-Port 10BASE-T/100BASE-TX/1000BASE-T is a versatile, easy-to-use switch. It is ideal for users who want the high-speed performance of 10/100/1000 switching but do not need sophisticated management capabilities. The Baseline 10/100/1000 Switch 6-Port can be rackmounted or free standing. The Baseline 10/100/1000 Switch 6-Port includes: Servers with 1000Mbps connections Baseline Hub with 10Mbps connection Baseline 10/100/1000 Switch 1000Mbps connections T One power cord T One mounting kit T Four standard height self-adhesive feet T A card with details of online registration The Switch can be powered either from the AC mains supply, or through an optional 3Com® SuperStack 3 Advanced Redundant Power System (3C16071A). [. . . ] Ces conditions ne sont maintenues que si l'équipement auquel il est raccordé fonctionne dans les mêmes conditions. Branchez uniquement un Advanced Redundant Power System (3C16070, 3C16071 ou 3C16071A) ou un Redundant Power System (3C565047) sur la prise femelle du Redundant Power System. Etats-Unis et Canada: s s s s Le cordon doit avoir reçu l'homologation des UL et un certificat de la CSA. Le cordon souple doit respecter, à titre minimum, les spécifications suivantes: calibre 18 AWG type SV ou SJ à 3 conducteurs Le cordon doit être en mesure d'acheminer un courant nominal d'au moins 10 A. La prise femelle de branchement doit être du type à mise à la terre (mise à la masse) et respecter la configuration NEMA 5-15P (15 A, 125 V) ou NEMA 6-15P (15 A, 250 V). La prise mâle d'alimentation doit respecter la section 107-2 D1 de la norme DK2 1a ou DK2 5a. La prise mâle d'alimentation doit respecter la norme SEV/ASE 1011. La prise secteur doit être conforme aux normes CEE 7/7 ("SCHUKO") LE cordon secteur doit porter la mention <HAR> ou <BASEC> et doit être de type HO3VVF3GO. 75 (minimum). Danemark: Suisse: Europe s s s s WICHTIGE SICHERHEITSINFORMATIONEN Bitte unbedingt vor dem Einbauen des Baseline 10/100/1000 Switch 6-Port Einheit die folgenden Sicherheitsanweisungen durchlesen. WARNUNG: Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen. T T T T s T T Wenn die Baseline 10/100/1000 Switch 6-Port Einheit in einer Stapel mit anderen SuperStack II Hub Einheiten eingebaut werden soll, muß die Baseline 10/100/1000 Switch 6-Port Einheit unter die schmaleren Hub Einheiten eingebaut werden. Das Gerät nicht an eine Wechselstromsteckdose anschließen, die nicht geerdet ist. Das Gerät muß an eine geerdete Steckdose angeschlossen werden, die die internationalen Sicherheitsnormen erfüllt. Der Gerätestecker (der Anschluß an das Gerät, nicht der Wandsteckdosenstecker) muß eine passende Konfiguration für einen Geräteeingang gemäß EN60320/IEC320 haben. Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen werden. Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen (Sicherheitskleinstspannung) gemäß IEC 60. Diese Bedingungen sind nur gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter SELV-Bedingungen betrieben werden. Nur ein Advanced Redundant Power System (3C16070, 3C16071 oder 3C16071A) oder Redundant Power System (3C565047) an den Redundant Power System Anschluß anschließen. Stromkabel. Dies muss von dem Land, in dem es benutzt wird geprüft werden: Schweiz s Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen einhalten. Europe s s Das Netzkabel muß vom Typ HO3VVF3GO. 75 (Mindestanforderung) sein und die Aufschrift <HAR> oder <BASEC> tragen. Der Netzstecker muß die Norm CEE 7/7 erfüllen ("SCHUKO"). 5 TECHNICAL INFORMATION Related Standards The SuperStack 3 Baseline 10/100/1000 Switch 6-Port 10BASE-T/100BASE-TX/1000BASE-T has been designed to the following standards: Functional ISO 8802-3, IEEE 802. 3 (Ethernet), IEEE 802. 3u (Fast Ethernet), IEEE 802. 3ab (Gigabit Ethernet), IEEE 802. 3x (Flow Control), IEEE 802. 1D (Bridging) UL 1950, EN 60950, CSA 22. 2 #950, IEC 60950 EN 55022 Class A, FCC Part 15 Subpart B Class A, ICES-003 Class A, VCCI Class A, AS/NZS 3548 Class A, CNS 13438 Class A EN 55024 Width Depth Height Weight Mounting Physical 440 mm (17. 3 in. ) 247. 5 mm (9. 7 in. ) 43. 6 mm (1. 7 in. ) or 1U 2. 85 kg (6. 3 lb) Free standing, or 19-inch rack mounted using the mounting kit supplied Safety EMC Emissions Electrical Power Inlet AC Line Frequency Input Voltage Current Rating Maximum Power Consumption IEC 320 50/60 Hz 100­240 VAC 3 A (maximum) 75 W 256 BTU/hr Immunity Environmental Operating Temperature Humidity Standard 0­50°C (32­122 °F) 10­90% (non-condensing) EN 60068 (IEC 68)--various parts Maximum Power Dissipation 3COM LIMITED WARRANTY This warranty applies to customers located in the United States, Australia, Canada (except Quebec), Ireland, New Zealand, U. K. , and other English language countries, and countries for which a translation into the local language is not provided. SuperStack 3 Baseline 10/100/1000 Switch 6-Port 10BASE-T/100BASE-TX/ 1000BASE-T HARDWARE: 3Com warrants to the end user ("Customer") that this hardware product will be free from defects in workmanship and materials, under normal use and service, for the following length of time from the date of purchase from 3Com or its authorized reseller: Lifetime, for as long as the original Customer owns the product (not transferable to a subsequent end user) 3Com's sole obligation under this express warranty shall be, at 3Com's option and expense, to repair the defective product or part, deliver to Customer an equivalent product or part to replace the defective item, or if neither of the two foregoing options is reasonably available, 3Com may, in its sole discretion, refund to Customer the purchase price paid for the defective product. 3Com warrants any replaced or repaired product or part for ninety (90) days from shipment, or the remainder of the initial warranty period, whichever is longer. SOFTWARE: 3Com warrants to Customer that each software program licensed from it, except as noted below, will perform in substantial conformance to its program specifications, for a period of ninety (90) days from the date of purchase from 3Com or its authorized reseller. 3Com warrants the media containing software against failure during the warranty period. No updates are provided, unless specifically included in the Included Services section. 3Com's sole obligation under this express warranty shall be, at 3Com's option and expense, to refund the purchase price paid by Customer for any defective software product, or to replace any defective media with software which substantially conforms to applicable 3Com published specifications. [. . . ] -- Plug the equipment into a different outlet so that equipment and receiver are on different branch circuits. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: How to Identify and Resolve Radio-TV Interference Problems This booklet is available from the U. S. In order to meet FCC emissions limits, this equipment must be used only with cables which comply with IEEE 802. 3. VCCI Statement BSMI Statement TECHNICAL SUPPORT For further information on obtaining support, refer to the Technical Support information in the User Guide that accompanies the Switch, or visit our Support Web site: http://www. support. 3com. com Alternatively, the following numbers may be used for technical support: Telephone Number 10800 61 00137 or 021 6350 1590 800 6161 463 00798 611 2230 (0)2 3455 6455 0080 611 261 001 800 611 2000 Country Asia, Pacific Rim Australia Hong Kong India Indonesia Japan Malaysia New Zealand Pakistan Philippines Telephone Number 1 800 678 515 800 933 486 +61 2 9937 5085 001 800 61 009 0031 61 6439 1800 801 777 0800 446 398 +61 2 9937 5085 1235 61 266 2602 Country P. R. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE 3COM SS3 BASELINE 100/1000 SW 6-PORT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual 3COM SS3 BASELINE 100/1000 SW 6-PORT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.