User manual 3COM SS II ADVANCED RPS 60W MODULE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual 3COM SS II ADVANCED RPS 60W MODULE. We hope that this 3COM SS II ADVANCED RPS 60W MODULE user guide will be useful to you.


3COM SS II ADVANCED RPS 60W MODULE : Download the complete user guide (132 Ko)

Manual abstract: user guide 3COM SS II ADVANCED RPS 60W MODULE

Detailed instructions for use are in the User's Guide.

[. . . ] Superseded Products The following superseded products may be powered from the Advanced RPS. Again their usage is subject to the total power limitation of 480 watts. Superseded Products requiring a 60 watt Power Module LinkBuilder Hubs 3C215A Hub 100 Management Unit 3C250-TX FMS 100 TX 3C16665 FMS II Fiber (also with 3C16630A or 3C16632 Management Module and 3C1206X Transceiver Module fitted) 3C16670 FMS II 12-port TP (also with 3C16630A or 3C16632 Management Module and 3C1206X Transceiver Module fitted) 3C16671 FMS II 24-port TP (also with 3C16630A or 3C16632 Management Module and 3C1206X Transceiver Module fitted) 3C16672 FMS II Telco (also with 3C16630A or 3C16632 Management Module and 3C1206X Transceiver Module fitted) 3C510510B FMS TR 12-port 3C510511B FMS TR 24-port NetBuilder Routers 3C8200C NetBuilder Remote Office 200 3C8201C NetBuilder Remote Office 201 3C8221C NetBuilder Remote Office 221 3C8222C NetBuilder Remote Office 222 3C8223C NetBuilder Remote Office 223 3C8224C NetBuilder Remote Office 224 3C8227C NetBuilder Remote Office 227 3C8228C NetBuilder Remote Office 228 3C8323C 3C8327C 3C8421C 3C8422C 3C8423C 3C8424C 3C8427C 3C8523C 3C8527C LinkSwitch 3C16900 3C16901 3C16940 NetBuilder Remote Office 323 NetBuilder Remote Office 327 NetBuilder Remote Office 421 NetBuilder Remote Office 422 NetBuilder Remote Office 423 NetBuilder Remote Office 424 NetBuilder Remote Office 427 NetBuilder Remote Office 523 NetBuilder Remote Office 527 LinkSwitch 1000 24-port (also with 3C1206x or 3C16920/2 modules fitted) LinkSwitch 1000 12-port (also with 3C1206x or 3C16920/2 modules fitted) LinkSwitch 3000 (also with 3C1206x or 3C16920/2 modules fitted) LinkSwitch 3000 TP (also with 3C16920/2 modules fitted) 3C32700A Switch 2700 OC-3 Multimode ATM 3C32710A Switch 2700 DS-3 ATM 3C32711A Switch 2700 OC-3 Singlemode ATM AccessBuilder 3C7204 AccessBuilder 2204 3C7208 AccessBuilder 2208 LinkConverter 3C8252A LinkConverter II 252 3C8254A LinkConverter II 254 3C8352A LinkConverter II 352 3C16941 ADVANCED RPS POWER MODULES (3C16072 & 3C16073) USER GUIDE Installing The Module Power Module Usage s You must not connect units with a total power requirement of more than 480 watts to any one chassis. s Single Power Modules must be considered as supplying their rated power. [. . . ] If the product you are connecting to the Power Module does not have the auto-enable feature (see SuperStack II Advanced RPS User Guide, part number DUA1607-0AAA0X), ensure the mains cable is removed from it before attempting to connect it to the Advanced RPS. Superseded Product requiring a 100 watt Power Module 3C16900 3C16901 3C16940 3C16941 3C32700A 3C32710A 3C32711A 3C220000A LinkSwitch 1000 24-port with 3C16930 module fitted LinkSwitch 1000 12-port with 3C16930 module fitted LinkSwitch 3000 with 3C16930 module fitted LinkSwitch 3000 TP with 3C16930 module fitted Switch 2700 OC-3 Multimode ATM Switch 2700 DS-3 ATM Switch 2700 OC-3 Singlemode ATM LinkSwitch 2200 Introduction The SuperStackTM II Advanced RPS Power Modules are designed to provide redundant power supplies, from the SuperStack II Advanced RPS chassis (3C16070/1), to the products in 3Com's SuperStack II range. There are two modules; a 60 watt capacity unit (3C16072) to supply most of the products and a 100 watt unit (3C16073) for those products with a higher power requirement. To connect the power module to the active units, use only the cables supplied with this module or the special `Y' cables available from your supplier. For more general information and warranty details for these products, please refer to SuperStack II Advanced RPS User Guide, part number DUA1607-0AAA0X. The optional SuperStack II Advanced RPS Management Module provides management information to a Network Manager. Details of the management functions are in the Management Module user guide, part number DUA1608-0AAA0X. This guide is written for the installation engineer and the network administrator who manages and maintains the network. ! DISCLAIMER Information in this document is subject to change without notice and does not represent a commitment on the part of 3Com Ireland. 3Com Ireland reserves the right to revise or change this document without obligation of 3Com Ireland to notify any person of the revisions or changes. Information contained in this document is believed to be accurate at the time of publication but no liability whatsoever can be accepted by 3Com Ireland arising out of any use of this information. This document, or any part of it, must not be copied or reproduced on any medium without the prior consent of 3Com Ireland. In the unlikely event that this product is found to be damaged on arrival, or fails to function once installed, you should contact your distributor or reseller for advice. Safety Information L'Information de Sécurité Sicherheitsinformationen ! ACKNOWLEDGEMENTS 3Com, AccessBuilder, NetBuilder, LinkSwitch and LinkBuilder are registered trademarks of 3Com Corporation. Registered trademarks are registered in the United States, and may or may not be registered in other countries. Other brand and product names may be registered trademarks or trademarks of their respective holders. Please read the safety information in the Advanced RPS Chassis User Guide before installing the module. Veuillez lire les instructions de sécurité dans le manual d'utilisation du chassis de l'Advanced RPS avant d'installer le module. Lesen sie vor der Installation des Modules die Sicherheitsinformationen in der Advanced RPS Gebrachsanweisung. ! Part Number: DUA1607-2AAA02 Revision: 00 Issued:July 11th, 1997 © 1997 3Com Technologies Power Supply And Fuses All power is supplied and fused from the Advanced RPS chassis. There are no user-replaceable fuses on the Power Modules. Technical Information Mechanical Weight Size 550 g (1. 21 lb) 272 x 87 mm (10. 7 x 3. 4 in) 3C16072 2. 5 amperes 1 ampere 8. 5 amperes 3C16073 2. 5 amperes 1 ampere 15 amperes LEDs LED Function State Indication Input Denotes OK presence Green of AC power. [. . . ] The details are, we believe, correct at the time of printing this manual, but may change. If you are in doubt, consult the product user guide or your supplier for the latest information. Power Module 1/ DC Cable not connected. Power Module present, Yellow LED ON 1/ Power Module connected to SuperStack II unit whose DC requirement exceeds the available DC output power. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE 3COM SS II ADVANCED RPS 60W MODULE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual 3COM SS II ADVANCED RPS 60W MODULE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.