User manual 3COM SECPATH U200M

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual 3COM SECPATH U200M. We hope that this 3COM SECPATH U200M user guide will be useful to you.


3COM SECPATH U200M : Download the complete user guide (3081 Ko)

Manual abstract: user guide 3COM SECPATH U200M

Detailed instructions for use are in the User's Guide.

[. . . ] H3C SecPath U200 Series Unified Threat Management Products Installation Manual Hangzhou H3C Technologies Co. , Ltd. http://www. h3c. com Manual Version: 5PW101-20090520 Copyright © 2009, Hangzhou H3C Technologies Co. , Ltd. and its licensors All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co. , Ltd. Trademarks H3C, , Aolynk, , H3Care, , TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V2G, VnG, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co. , Ltd. All other trademarks that may be mentioned in this manual are the property of their respective owners. Notice The information in this document is subject to change without notice. [. . . ] For the association between the Comware application version and the BootWare program version, refer to the version configuration information in Release Notes. 6-3 Figure 6-1 BootWare and Comware programs upgrade flow Start Comware application N Upgrade Comware ?Y Choose the right Comware application file Choose an upgrade method Through Ethernet interface Xmodem TFTP FTP Upgrade End BootWare Menu BootWare Main Menu When the device is powered on, the system first initializes the memory. After the initialization, the system, the U200-A for example, runs the extended BootWare, and the following information is displayed on the console terminal: The information displayed on the terminal may vary with different BootWare versions. System is starting. . . Booting Normal Extend BootWare. . . . ************************************************************************** * * * ************************************************************************** H3C SecPath UTM200-A BootWare, Version 1. 10 * * * 6-4 Copyright (c) 2004-2008 Hangzhou H3C Technologies Co. , Ltd. Compiled Date CPU Type CPU L1 Cache CPU Clock Speed Memory Type Memory Size Memory Speed BootWare Size Flash Size CPLD Version PCB Version : May 7 2008 : XLS208 : 32KB : 750MHz : DDR2 SDRAM : 1024MB : 533MHz : 1536KB : 32MB : 1. 0 : Ver. A BootWare Validating. . . Press Ctrl+B to enter extended boot menu. . . Press Ctrl+B to enter the extended BootWare menu; otherwise, the system enters the self extraction process of applications. You must press Ctrl+B in four seconds when "Press Ctrl+B to enter extended boot menu" appears. Otherwise, the system will read and decompress the application file instead of entering the extended BootWare menu. After the system enters the self extraction process of applications, if you want to enter the extended BootWare menu, you need to reboot the device. The extended BootWare menu is referred to as BootWare main menu in this manual unless otherwise specified. Press Ctrl+B when "Press Ctrl+B to enter extended boot menu. . . " appears. The system displays: Please input BootWare password: You can try up to three times to enter the correct BootWare password (the initial password is null). If you fail to provide the correct password with three attempts, you need to reboot the system. After you type the correct password, the system enters the BootWare main menu: Note: The current operating device is cfa0 Enter < Storage Device Operation > to select device. ==================<EXTEND-BOOTWARE MENU>===================== | <1> Boot System | <2> Enter Serial SubMenu | <3> Enter Ethernet SubMenu | <4> File Control | <5> Modify BootWare Password | <6> Skip Current System Configuration | | | | | | 6-5 | <7> BootWare Operation Menu | <8> Clear Super Password | <9> Storage Device Operation | <0> Reboot | | | | ============================================================= Enter your choice(0-9): The menu is described in the following table. Table 6-1 BootWare main menu Menu item <1> Boot System <2> Enter Serial SubMenu <3> Enter Ethernet SubMenu <4> File Control <5> Modify BootWare Password <6> Skip Current System Configuration <7> BootWare Operation Menu Description Boot the system application from the CF card Enter the serial submenu. This is a one-time operation and therefore does not take effect at a reboot. Refer to the "BootWare Operation Submenu" section on page 6-8. <8> Clear Super Password The super password is used in user level switching. At subsequent reboots, you will be asked to provide the super password. <9> Storage Device Operation <a> Reboot Select the storage medium from which the system is to boot. Reboot the device. Serial Submenu Select 2 on the BootWare main menu to enter the serial submenu, where you can upgrade the application and BootWare with Xmodem. The system displays: =====================<Enter Serial SubMenu>================== |Note:the operating device is flash | <1> Download Application Program To SDRAM And Run | <2> Update Main Application File | <3> Update Backup Application File | <4> Update Secure Application File | | | | | 6-6 | <5> Modify Serial Interface Parameter | <0> Exit To Main Menu | | ============================================================= Enter your choice(0-5): Items on this submenu are described in Table 6-2. Table 6-2 BootWare serial submenu Menu item <1> Download Application Program To SDRAM And Run <2> Update Main Application File <3> Update Backup Application File <4> Update Secure Application File <5> Modify Serial Interface Parameter <0> Exit To Main Menu Description Download the application to the SDRAM through the serial interface and run the program. Return to the BootWare main menu. Ethernet Submenu Select 3 on the BootWare main menu to enter the Ethernet submenu, where you can upgrade the application and BootWare with FTP/TFTP. The system displays: ==================<Enter Ethernet SubMenu>=================== |Note:the operating device is flash | <1> Download Application Program To SDRAM And Run | <2> Update Main Application File | <3> Update Backup Application File | <4> Update Secure Application File | <5> Modify Ethernet Parameter | <0> Exit To Main Menu | < Ensure The Parameter Be Modified Before Downloading! [. . . ] 5cm Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. The unit/system must be connected to the protection ground before operation. And the cross-section of protective earthing conductor shall be at least 1. 0 mm2 Das System muss vor der ständigen Inbetriebnahme geerdet werden. / 1. 0mm2 For AC supplied model: The device applies to TN power systems. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE 3COM SECPATH U200M




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual 3COM SECPATH U200M will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.