User manual 3COM LS-S3610-52P-OVS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual 3COM LS-S3610-52P-OVS. We hope that this 3COM LS-S3610-52P-OVS user guide will be useful to you.


3COM LS-S3610-52P-OVS : Download the complete user guide (1316 Ko)

Manual abstract: user guide 3COM LS-S3610-52P-OVS

Detailed instructions for use are in the User's Guide.

[. . . ] H3C S3610 Series Ethernet Switches Installation Manual Hangzhou H3C Technologies Co. , Ltd. http://www. h3c. com Manual Version: T2-20080526-C-1. 07 Copyright © 2006-2008, Hangzhou H3C Technologies Co. , Ltd. and its licensors All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co. , Ltd. Trademarks H3C, , Aolynk, , H3Care, , TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V2G, VnG, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co. , Ltd. All other trademarks that may be mentioned in this manual are the property of their respective owners. Notice The information in this document is subject to change without notice. [. . . ] Fixed interface module On the rear panel of the S3610-52M/S3610-52M-DC switch, there is a fixed interface module that cannot be uninstalled. On the interface module, there are four Gigabit SFP ports and four 10/100/1000 Mbps Ethernet ports. An SFP port and an Ethernet port form a Combo port, and only one of the two ports forming a Combo port takes effect at a time. The corresponding relationship between the SFP ports and Ethernet ports that form a Combo port are listed in the following table: Table 1-10 Combo port list SFP port 49 50 51 52 53 54 55 56 Ethernet port The supported SFP modules for the fixed interface module are listed in Table 1-4. 1-24 Installation Manual H3C S3610 Series Ethernet Switches Chapter 1 Product Overview 1. 7 S3610 Series Ethernet Switches System Features Table 1-11 S3610 series Ethernet switches system features Item S3610-52P S3610-28P Physical dimensions (H × W × D) S3610-28TP S3610-28F S3610-52M/S3610-52M-DC S3610-52P S3610-28P Weight S3610-28TP S3610-28F S3610-52M/S3610-52M-DC Management port One console port S3610-28P 24 × 10/100 Mbps electrical ports and 4 × 1000 Mbps SFP ports 24 × 10/100 Mbps electrical ports, 2 × 1000 Mbps SFP ports and 2 × 10/100/1000 Mbps electrical ports 48 × 10/100 Mbps electrical ports and 4 x 1000 Mbps SFP ports 24 × 100 Mbps SFP ports, 2 x 1000 Mbps SFP ports and 2 x 10/100/1000 Mbps electrical ports Decided by the inserted modules. Up to 48 × 10/100 Mbps electrical ports or 48 × 100 Mbps SFP ports. On the rear panel, there are 4 × 1000 Mbps fixed SFP ports and 4 × 10/100/1000 Mbps fixed electrical ports. 86 × 440 × 420 mm (3. 4 × 17. 2 × 16. 5 in. ) 3. 8 kg (8. 4 lb. ) 3. 6 kg (7. 9 lb. ) 3. 7 kg (8. 2 lb. ) 3. 8 kg (8. 4 lb. ) 8. 5 kg (18. 7 lb. ) 43. 6 × 440 × 260 mm (1. 7 × 17. 3 × 10. 2 in. ) H3C S3610 series S3610-28TP S3610-52P Service port S3610-28F S3610-52M/S3 610-52M-DC The S3610 series supports both AC input and DC input. AC input: Rated voltage range: 100 VAC to 240 VAC; 50 Hz or 60 Hz Input voltage Max voltage range: 90 VAC to 264 VAC; 50 Hz or 60 Hz DC input: Rated voltage range: ­48 VDC to ­60 VDC Max voltage range: ­36 VDC to ­72 VDC 1-25 Installation Manual H3C S3610 Series Ethernet Switches Chapter 1 Product Overview Item S3610-52P S3610-28P Power consumption (fully loaded) S3610-28TP S3610-28F H3C S3610 series 45 W 35 W 40 W 60 W 110 W S3610-52M/S3610-52M-DC Operating temperature Relative humidity (noncondensi ng) 0°C to 45°C (32°F to 113°F) 10% to 90% 1-26 Installation Manual H3C S3610 Series Ethernet Switches Chapter 2 Installation Preparation Chapter 2 Installation Preparation 2. 1 Safety Precautions To avoid any device impairment and bodily injury caused by improper use, observe these rules: Before cleaning the switch, unplug the power plug of the switch first. Ensure proper ventilation of the equipment room and keep the ventilation vents of the switch free of obstruction. Make sure that the operating voltage is the same one labeled on the switch. Do not open the chassis while the switch is operating or when electrical hazards are present to avoid electrical shocks. When replacing interface cards, wear ESD-protective gloves to avoid damaging the cards. 2. 2 Installation Site The S3610 series must be used indoors. You can mount your switch in a rack or on a tabletop/workbench, but make sure: Adequate clearance is reserved at the air inlet/exhaust vents for ventilation. To ensure normal operation and long service life of your VG, install it in an environment that meets the requirements described in the following subsections. 2. 2. 1 Temperature/Humidity You must maintain a proper temperature and humidity in the equipment room. Long-term high humidity may lead to bad insulation, electricity leakage, mechanical property changes, and corrosion. However, if the relative humidity is two low, captive screws may become loose as the result of contraction of insulation washers and static electricity may be produced in a dry environment to jeopardize the CMOS circuits on the device. High temperature is the most undesirable condition, 2-1 Installation Manual H3C S3610 Series Ethernet Switches Chapter 2 Installation Preparation because it accelerates aging of insulation materials and can thus significantly lower reliability and service life of your switch. 2. 2. 2 Cleanness Dust is a hazard to the operating safety of your device. The dust accumulated on the chassis can be adsorbed by static electricity and result in poor contact of metal connectors or metal contact points. This can not only shorten the service life of your device but also cause communications failures. When the relative indoor humidity is low, electrostatic adsorption is more likely to happen. The contents of the dust must be limited as shown in the following table: Table 2-1 Dust content limits in an equipment room Substance Dust Unit 3 × 10 Particles/m³ Content 4 (No visible dust on the tabletop for three days) Remark: the diameter of a dust particle 5 m Besides dust, there are rigorous limits on the harmful gases that can accelerate the erosion and aging of metals, such as salts, acids, and sulfides, as shown in the following table. Table 2-2 Harmful gas limits in the equipment room Gas SO2 H2S NH3 Cl2 0. 2 0. 006 0. 05 0. 01 Maximum (mg/m3) 2. 2. 3 Electromagnetic Susceptibility The operation of your switch can be affected by external interferences, such as conducted emission by capacitance coupling, inductance coupling, electromagnetic wave radiation, and common impedance (including the grounding system) coupling, and leads (power cords, signaling cables and output wires. [. . . ] Power switch Normal operation indicator (green): On means that the arrester works normally. Power socket (complied with IEC standard), connected to the power supply of the equipment room through power cord Mainboard Multipurpose power socket, connected to the device protected by the arrester Overload auto protector, which can be manually reset. Figure A-1 Diagram of lightning arrester A-1 Installation Manual H3C S3610 Series Ethernet Switches Appendix A Lightning Protection of the Switch Caution: Make sure that the arrester is well grounded before using the lightning arrester for power. After inserting AC power cord plug of switch into the socket of lightning arrester, if the green LED is on and the red LED does not alarm, it means that the lightning arrester of power is running and the function of lightning protection has taken effect. You should correctly locate the problem, whether it is caused because the ground wire of the arrester is not well grounded or because the live and zero wires are connected in reverse direction. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE 3COM LS-S3610-52P-OVS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual 3COM LS-S3610-52P-OVS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.