User manual 3COM H3C SECPATH F5000-A5 ADVANCED VPN FIREWALL 12-PORT GIGABIT ETHERNET MODULE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual 3COM H3C SECPATH F5000-A5 ADVANCED VPN FIREWALL 12-PORT GIGABIT ETHERNET MODULE. We hope that this 3COM H3C SECPATH F5000-A5 ADVANCED VPN FIREWALL 12-PORT GIGABIT ETHERNET MODULE user guide will be useful to you.


3COM H3C SECPATH F5000-A5 ADVANCED VPN FIREWALL 12-PORT GIGABIT ETHERNET MODULE : Download the complete user guide (6940 Ko)

Manual abstract: user guide 3COM H3C SECPATH F5000-A5 ADVANCED VPN FIREWALL 12-PORT GIGABIT ETHERNET MODULE

Detailed instructions for use are in the User's Guide.

[. . . ] H3C SecPath F5000-A5 Firewall Installation Manual Hangzhou H3C Technologies Co. , Ltd. http://www. h3c. com Manual Version: 5PW101-20090424 Copyright © 2008-2009, Hangzhou H3C Technologies Co. , Ltd. and its licensors All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co. , Ltd. Trademarks H3C, , Aolynk, , H3Care, , TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V2G, VnG, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co. , Ltd. All other trademarks that may be mentioned in this manual are the property of their respective owners. Notice The information in this document is subject to change without notice. [. . . ] Upgrade the main application file Upgrade the backup application file Upgrade the secure application file Modify serial port parameters Return to the main menu Ethernet Submenu Select 3 on the main menu to enter the Ethernet submenu, where you can upgrade application files and the BootWare program through FTP or TFTP. The system displays: =========================<Enter Ethernet SubMenu>===================== |Note:the operating device is cfa0 | <1> Download Application Program To SDRAM And Run | <2> Update Main Application File | <3> Update Backup Application File | <4> Update Secure Application File | <5> Modify Ethernet Parameter | <0> Exit To Main Menu | < Ensure The Parameter Be Modified Before Downloading!> | | | | | | | | ====================================================================== Enter your choice(0-5): Items on this submenu are described in Table 6-3. Table 6-3 Ethernet submenu Menu item <1> Download Application Program To SDRAM And Run <2> Update Main Application File 6-8 Description Download an application to SDRAM and run the program. Upgrade the main application file Menu item <3> Update Backup Application File <4> Update Secure Application File <5> Modify Ethernet Parameter <0> Exit To Main Menu Description Upgrade the backup application file Upgrade the secure application file Modify Ethernet interface parameters Return to the main menu File Control Submenu Select 4 on the main menu to enter the file control submenu, where you can view, modify, or delete application files. The system displays: ==============================<File CONTROL>========================== |Note:the operating device is cfa0 | <1> Display All File(s) | <2> Set Application File type | <3> Delete File | <0> Exit To Main Menu | | | | | ====================================================================== Enter your choice(0-3): Items on this submenu are described in Table 6-4. Table 6-4 File control submenu Menu item <1> Display All File(s) <2> Set Application File type <3> Delete File <0> Exit To Main Menu Display all files. Description BootWare Operation Submenu Select 7 on the main menu to enter the BootWare operation submenu: ========================<BOOTWARE Operation Menu>===================== |Note:the operating device is cfa0 | <1> Backup Full BootWare | <2> Restore Full BootWare | <3> Update BootWare By Serial | <4> Update BootWare By Ethernet | <0> Exit To Main Menu | | | | | | ====================================================================== Enter your choice(0-4): Items on this submenu are described in Table 6-5. 6-9 Table 6-5 BootWare operation submenu Menu item <1> Backup Full BootWare <2> Restore Full BootWare <3> Update BootWare By Serial <4> Update BootWare By Ethernet <0> Exit To Main Menu Description Back up the entire BootWare. Return to the main menu. Storage Device Operation Submenu Select 9 on the main menu to enter the storage device operation submenu: ==========================<DEVICE CONTROL>============================ |<1> Display All Available Nonvolatile Storage Device(s) |<2> Set The Operating Device |<3> Set The Default Boot Device |<0> Exit To Main Menu | | | | ====================================================================== Enter your choice(0-3): Items on this submenu are described in Table 6-6. Table 6-6 Storage device operation submenu Menu item <1> Display All Available Nonvolatile Storage Device(s) <2> Set The Operating Device <3> Set The Default Boot Device <0> Exit To Main Menu Description Display all available storage devices. Return to the main menu. Upgrading BootWare and Applications Through a Serial Port Introduction to Xmodem Xmodem is used for upgrading BootWare and applications through a serial port. Xmodem is a file transfer protocol that is widely used due to its simplicity and high performance. It supports two types of data packets (128 bytes and 1 KB), two check methods (checksum and CRC), and error packet retransmission mechanism (generally the maximum number of retransmission attempts is 10). An Xmodem transmission procedure is completed by the cooperation of a receiving program and a sending program. The receiving program sends a negotiation character to negotiate a packet check method. After the negotiation, the sending program starts to transmit data packets. Upon receiving a complete data packet, the receiving program checks the packet using the agreed method. If the check succeeds, the receiving program sends an acknowledgement character and the sending program proceeds to send another packet. 6-10 If the check fails, the receiving program sends a negative acknowledgement character and the sending program retransmits the packet. Modifying Serial Port Parameters In actual applications, you may need to make the serial port baud rate higher to reduce upgrading time or make it lower to guarantee transmission reliability. Step1 Enter the main menu and select 2 to enter the serial submenu, and then select 5 to modify the baud rate. The system displays the following: ============================<BAUDRATE SET>============================ |Note:'*'indicates the current baudrate | Change The HyperTerminal's Baudrate Accordingly | | |-----------------------<Baudrate Available>-------------------------| |<1> 9600(Default) * |<2> 19200 |<3> 38400 |<4> 57600 |<5> 115200 |<0> Exit | | | | | | ====================================================================== Enter your Choice(0-5): Step2 Select a proper baud rate. For example, select 5 for a baud rate of 115200 bps and the system displays: Baudrate has been changed to 115200 bps. Please change the terminal's baudrate to 115200 bps, press ENTER when ready. At this time, the baud rate of the serial port of the firewall is 115200 bps, while that of the terminal is still 9600 bps. [. . . ] durch feuchte Gegenstände) mit Hochspannung und Wechselstromversorgung kann zu tödlichen Unfällen führen. AC During the installation of AC power supply facility, the local safety regulations must be followed. The personnel who install the AC facility must be qualified for high voltage and AC operations. Bei der Installation der Wechselstromversorgung sind die örtlichen Sicherheitsbestimmungen zu beachten. Das Personal muss besonders qualifiziert sein für das Arbeiten mit Hochspannung und Wechselstrom. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE 3COM H3C SECPATH F5000-A5 ADVANCED VPN FIREWALL 12-PORT GIGABIT ETHERNET MODULE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual 3COM H3C SECPATH F5000-A5 ADVANCED VPN FIREWALL 12-PORT GIGABIT ETHERNET MODULE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.